General Description - Lincoln Electric Infinity-Pak K3926-1 Operator's Manual

Station
Table of Contents

Advertisement

INFINITY-PAK STATION

GENERAL DESCRIPTION

This guide is designed to assist the user whose primary responsibility
is to operate and maintain the Infinity-Pak Wire Dispensing System.
This manual provides specific information on installation, safety, basic
operation, and maintenance. Please read, understand and follow all
safety procedures.The Infinity-Pak Wire Dispensing System utilizes a
unique process that joins the end wire from an empty box with the
start wire of the next full box, eliminating costly downtime for wire
changeover and optimizing production time. A smooth operating wire
guide arm handles the wire transfer during the automatic change, with
no manual operator action required. With our easy-to-use Butt Welder,
both butt-welding and flash removal operations take only seconds. We
recommend that the customer shuts off the arc welding process while
butt welding the two boxes. If they touch electrically live wire, they risk
getting shocked. The Infinity-Pak Wire Dispensing System works with
either one or two station robotic cells (2 or 4 boxes). A convenient
Docking Station that holds the Butt Welder and a deburring tool is also
available for this package. Made in the U.S.A.
SAFETY PRECAUTIONS:
The Infinity-Pak Wire Dispensing System is designed to be safe to
operate, provided the user reads, understands and adheres to the
safety precautions listed below. Failure to adhere to these precautions
may result in personal injury and/or damage to the equipment.
WEAR EYE PROTECTION
• When butt welding the wire ends together
or deburring the wire after butt welding,
always wear eye protection.
WEAR PROTECTIVE GLOVES
• When butt welding the wire ends together
or deburring the wire after butt welding,
always wear protective gloves.
WARNING
ELECTRIC SHOCK CAN KILL
• Turn off arc welding power source before
performing butt welder operation.
• Do not touch wire when butt welding. The
wire is not safe to touch until after the
weld is finished. Keep hands and arms
away from charged wire.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate your self from work and ground.
• Always wear dry insulating gloves.
• CAUTION: Parts may be at welding voltage
during butt welding operation.
ALWAYS SECURE WIRE BOXES
• Ensure all wire boxes are firmly secured to
the Infinity-Pak Wire System with the
provided wratchet straps to avoid roll
away hazards.