Advertisement

Quick Links

IM3047
06/2017
REV01
TM
ARC TRACKER
OPERATOR'S MANUAL
ENGLISH
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA
www.lincolnelectric.eu
English
1
English

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric ARC TRACKER K3019-1

  • Page 1 IM3047 06/2017 REV01 ARC TRACKER OPERATOR’S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA www.lincolnelectric.eu English English...
  • Page 2: Table Of Contents

    THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 3: Technical Specification

    Technical Specification ARC TRACKER™ INPUT VOLTAGE AND CURRENT Model Input Voltage ± 10% Input Amperes K3019-1 120-230 V AC, 50/60 Hz 0,8-0,5 A RATED OPERATING RANGE NEMA EW1 Duty Cycle 100% 44 V DC 1000 A DC RATED OPERATING RANGE IEC60974-1 Duty Cycle 100% 44 V DC...
  • Page 4 THE LINCOLN ELECTRIC COMPANY EC DECLARATION OF CONFORMITY Manufacturer and technical documentation holder: The Lincoln Electric Company Address: 22801 St. Clair Ave. Cleveland Ohio 44117-1199 USA EC Company: Lincoln Electric Europe S.L. Address: c/o Balmes, 89 - 8 08008 Barcelona SPAIN...
  • Page 5: Electromagnetic Compatibility (Emc)

    Lincoln Electric. Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances.
  • Page 6: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 7: Installation And Operator Instructions

    SAFETY MARK: This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock. CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used.
  • Page 8 close as possible to the arc, e.g. at the contact tip, wire High Frequency Protection feeder, etc and to the work. The EMC classification of the ARC TRACKER™ is Product Specific Instructions Industrial, Scientific and Medical (ISM) group 2, class A. The ARC TRACKER™...
  • Page 9  The ARC TRACKER™ has been calibrated before being shipped from the factory. The Lincoln Electric Company recommends that end-users of its welding equipment evaluate the suitability of utilizing this product in their quality system, determine if periodic...
  • Page 10 Power-Up Sequence User Defined Parameters When power is applied to the ARC TRACKER™, the status light will flash green for up to 60 seconds. During this time the unit is performing a self test. The status Parameter Definition light will also flash green as a result of a system reset or Exit Setup Menu configuration change during operation.
  • Page 11 4/0 WELDING CABLES displayed energy value has an accuracy of +/-5%. VOLTAGE SENSE LEADS (FROM FRONT OF ARC TRACKER) The Lincoln Electric Company recommends that end- G. RED users of its welding equipment evaluate the suitability of H. BLACK utilizing the ARC TRACKER™ in their quality system.
  • Page 12 % Dev Equations: ARC TRACKER As Found - Reference Meter Value %Dev As Found = ×100% Reference Meter Value ARC TRACKER As Left - ARC TRACKER As Found %Dev As Left = ×100% Reference Meter Value Table D.1 Nominal Reference Arc Tracker %Deviation Arc Tracker...
  • Page 13 Adjustment Procedure: E. Turn on the power source to provide the maximum calibration current and voltage, e.g. 1000 A, 44 V. The ARC TRACKER™ will begin to display the voltage, amperage, & arc time, and will begin to calculate and display heat input.
  • Page 14 We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose,...
  • Page 15: Weee

    WEEE 07/06 Do not dispose of electrical equipment together with normal waste! In observance of European Directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility.
  • Page 16: Electrical Schematic

    Electrical Schematic WIRING DIAGRAM NOTE: this diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a partiuclar code is pasted inside the machine on one of the enclosure panels. If the diagram is ellegible, write to the Service Department for a raplacement.

Table of Contents