Hide thumbs Also See for Pipetman P2G:

Advertisement

G
User's Guide
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pipetman P2G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gilson Pipetman P2G

  • Page 1 User’s Guide...
  • Page 2: Table Of Contents

    To answer the current needs of the loyal GLP Features | 4 users of our pipette, and still conform to Gilson Description | 5 brand qualities, three improvements have been added to our mechanical series: Specifications | 6...
  • Page 3: Glp Features

    GLP Features Description The Serial Number is engraved on the body of the pipette. It provides unique identification of Color-coded your pipette and the date of manufacture. push button Ex : AA10369 Tip ejector button The Barcode on the box and the certificate of Thumbwheel conformity provide traceability of your pipette.
  • Page 4 ± 0.024 ≤0.012 ±0.08 ≤0.04 Each pipette is inspected and validated by qualified ≤0.012 ≤0.04 ± 0.025 ±0.08 technicians in accordance with the Gilson Quality (F144054P) (F144054M) Max. ± 0.030 ≤0.014 ±0.08 ≤0.04 System. Gilson declares that its manufactured Min.
  • Page 5: Pipetting

    Chapter 2 Chapter 3 PIPETTING SETTING ThE vOLUME The volume of liquid to be It is recommended to use PIPETMAN® DIAMOND P10G P20G Tips with the PIPETMAN G for optimum aspirated is set using the performance. These tips are made from pure volumeter.
  • Page 6: Pre-Rinse The Tips

    For the P2G and P10G Models Equipped with First stop Plastic Tip Ejector, Second stop A tip ejector extension is supplied to fit with D10 tips (short tips). To fit a tip ejector extension: Slide the extension over the tip holder.
  • Page 7: Guidelines For Good Pipetting

    Guidelines for Good Pipetting 10. You may remove the tip ejector, see ChAPTER 6 - MAINTENANCE to aspirate Make sure that you operate the push button from very narrow tubes. slowly and smoothly. After pipetting acids or other corrosive liquids that emit vapors, remove the tip ejector, the tip When aspirating, keep the tip at a constant holder, rinse, dry and lubricate the piston, see...
  • Page 8: Accessories

    TROUBLEShOOTING ACCESSORIES To make pipetting more comfortable and A quick inspection of the pipette may help you to more secure, Gilson has developed several detect a problem. accessories: You may download from the Gilson Pipette stands allow users to store pipettes website (www.gilson.com)
  • Page 9: Leak Test

    If a pipette fails this test, replace the O-ring and seal. After making sure that the pipette PIPETMAN P2G and P10G should not be is correctly reassembled, repeat this test. disassembled, so you may only replace the push button, tip ejector, dual position tip ejector and its adapter.
  • Page 10 If the piston assembly is changed, the pipette must be adjusted and calibrated in a local Gilson Service Center. As the models P2G and P10G contain miniaturized parts, it is best not to disassemble these pipettes yourself.
  • Page 11: Cleaning And Decontamination

    You may refer to the replaced. As the models P2G and P10G contain decontamination procedure miniaturized parts, it is best not to disassemble available on the Gilson website NOTICE (www.gilson.com). Liquid must these pipettes yourself, please contact your never enter the upper part local Gilson Service Center.
  • Page 12 Chemical Decontamination Internal The following components only can be immersed You may choose to decontaminate your pipette chemically, in accordance with your own in a cleaning solution: connecting nut, tip ejector, tip holder, piston assembly, seal and O-ring. procedures. Whatever decontaminant you use, check with the supplier of the decontaminant Disassemble the pipette as described in the that it is compatible with stainless steel and...
  • Page 13: Spare Parts

    Chapter 8 P2G (F144054P OR M) AND P10G (F144055P OR M)* P/N FOR P/N FOR SPARE PARTS DESCRIPTION P10G C+D+E Service Kit 1 level F144501 FA07001 A+B+F1 to F4 Service Kit 2 level F1619702 F1619712 Seal + O-ring (5 sets) F144861 FA07012 Service Kit 1...
  • Page 14: Warranty

    This warranty shall also be void in the event pipettes are altered or modified by any party other than Gilson or its designates. Gilson’s sole liability under this warranty shall be limited to, at Gilson’s sole...
  • Page 15 T: 608-836-1551 or 800-445-7661 • F 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs BP 145 • F-95400 Villiers-le-Bel, France T +33 (0) 1 34 29 50 00 • F +33 (0) 1 34 29 50 20 LT801122/C | ©2017 Gilson, Inc. All rights reserved.

Table of Contents