Troubleshooting by Indication on the Remote Controller
3.20 "E7" Malfunction of Outdoor Unit Fan Motor
E7
Remote Control
Display
ER*Q 011~016*
Applicable
Models
Malfunction of fan motor system is detected according to the fan speed detected by hall IC
Method of
when the fan motor runs.
Malfunction
Detection
When the fan runs with speed less than a specified one for 6 seconds or more when the fan
Malfunction
Decision
When malfunction is generated 4 times, the system shuts down.
Conditions
Malfunction of fan motor
Supposed
The harness connector between fan motor and PC board is left in disconnected, or faulty
Causes
Fan does not run due to foreign matters tangled
Clearing condition: Operate for 5 minutes (normal)
Open phase L1 or open phase N.
158
motor running conditions are met
connector
ESIE09-08B
Troubleshooting