ESIE09-08B
3.1.2 Setting Contents and Code No. – EKHBRD – Indoor unit
EKHBRD*AA
First
Second
code
code
Setting name
0
Remote control setup
00
User permission level
01
Room temperature compensation value
02
Not applicable. Do not change the default
value.
03
Status: space heating schedule timer mode
1
Automatic storage timing for domestic water heating
00
Status: night time storage
01
Night time storage start time
02
Status: day time storage
03
Day time storage start time
2
Automatic setback function
00
Status: setback operation
01
Setback operation start time
02
Setback operation stop time
3
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature
(Lo_Ti)
03
Set point at high ambient temperature
(Hi_Ti)
4
Disinfection function
00
Status: disinfection operation
01
Disinfection operation day selection
02
Disinfection operation start time
5
Automatic setback and disinfection set point
00
Set point: disinfection operation temperature
01
Disinfection operation time duration
02
Leaving water setback temperature
03
Room setback temperature
6
Option setup
00
Domestic hot water tank installed
01
Optional room thermostat installed
02
Backup heater kit activation
03
Solar kit activation
04
Benefit kWh power supply mode
Test Operation
Installer setting at variance with
default value
Date
Value
Date
Value
Field Setting
Default
value
Range
Step
2
2~3
1
0
–5~5
0.5
1 (ON)
0/1
1 (ON)
0/1
1 (ON)
0/1
1:00
0:00~
1:00
23:00
0
0/1
(OFF)
15:00
0:00~
1:00
23:00
1 (ON)
0/1
23:00
0:00~
1:00
23:00
5:00
0:00~
1:00
23:00
–10
–20~5
1
15
10~20
1
70
25~80
1
45
25~80
1
1 (ON)
0/1
Fri
Mon~Sun
23:00
0:00~
1:00
23:00
70
60~70
5
10
5~60
5
5
0~10
1
18
17~23
1
0
0/1
(OFF)
0
0/1
(OFF)
0
0/1
(OFF)
0
0/1
(OFF)
0
0/2
1
Unit
°C
hour
hour
hour
hour
°C
°C
°C
°C
hour
°C
min
°C
°C
81