Honeywell GasAlertQuattro Operator's Manual page 16

1, 2, 3, and 4 gas detector
Table of Contents

Advertisement

3.
4.
In normal operating mode, it is possible to display
measured values with calibration gas applied to
determine any measurement errors.
Shop for Gas products online at:
Attach and tighten the calibration cap onto the
detector and apply gas. Verify the visual, audible, and
vibrator alarms activate.
Close the regulator and remove the calibration cap.
The detector temporarily remains in alarm until the
gas clears from the sensors.
Note
CanarySense
www.
GasAlertQuattro
Bump Test
13
.com
1.888.610.7664