Refer to the following table for information about alarms and corresponding screens. For more information about alarms refer to the
GasAlertQuattro Technical Reference Guide.
Low Alarm
• Slow siren (upward tone)
• Slow flash
• Black box around gas flashes
• Vibrator alarm activates
High Alarm
• Fast siren (downward tone)
• Fast flash
• Black box around gas flashes
• Vibrator alarm activates
14
Shop for Gas products online at:
Alarm
Screen
H
S ppm
CO ppm
2
0
0.0
LOW
ALARM
19.5
0
O
%
LEL
2
H
S ppm
CO ppm
2
200
0.0
HIGH
ALARM
20.9
0
O
%
LEL
2
CanarySense
www.
Alarm
TWA Alarm
• Fast siren (downward tone)
• Fast flash
• Black box around gas flashes
• Vibrator alarm activates
%
STEL Alarm
• Fast siren (downward tone)
• Fast flash
• Black box around gas flashes
• Vibrator alarm activates
%
.com
Screen
H
S ppm
CO ppm
2
15.0
0
TWA
ALARM
20.9
0
O
%
LEL
%
2
H
S ppm
CO ppm
2
50
0.0
STEL
ALARM
20.9
0
O
%
LEL
%
2