WARNING!
Electrical shock hazard. Assume all parts are live.
Disconnect supply before servicing and installation.
Left side
of cavity
2 15/16"
(75mm)
Floor
Alternative electrical connection location
5 3/32"
(129mm)
ELECTRICAL SPECIFICATIONS
Supply
Service
PLUMBING SPECIFICATIONS
Supply
Pressure
Note:
Electrical connection can be located in an adjacent cabinet to either side of the fridge or above the fridge cavity.
●
●
We recommend to use an isolating switch that is easily accessible to the user after the refrigerator is installed.
●
●
Do not locate water or electricity in this area, keep clear of connections.
!
!
CAUTION:
Central area can only fit electrical plug if it is placed within a recessed cavity.
* Water fittings kit – The standard refrigerator does not include water fittings. Standard Fisher & Paykel water fittings
kit are available (part number: 841301). These parts need to be purchased separately by the customer and comply
with local regulations.
8
ELECTRICAL AND PLUMBING
!
31 1/2"
(800mm)
5 29/32"
(150mm)
4 11/32"
(110mm)
5 29/32"
4 11/32"
(150mm)
(110mm)
1/4" (6mm) hose or copper tubing*
min. 22psi (150kPa)
max. 120psi (827kPa) @ 68°F (20°C)
115VAC, 60Hz
10 amp circuit
Recommended area above
cavity for connections
Electrical
Plumbing
Electrical
Plumbing
11