Chapter 5 - Options; A - Level Detection Bleed Valve (Fig. 12); B -Advanced Filtration To The Compression Air Inlet (Fig. 13A And 13B) - Chicago Pneumatic CPF 175 Instruction Manual

Cp compressor
Hide thumbs Also See for CPF 175:
Table of Contents

Advertisement

Chapter 5 - Options

A - Level detection bleed valve (Fig. 12)

1 - Description
The BEKOMAT type level detection bleed valve allows all air
consumption to be avoided while the compressor is not running.
2 - Option overview
- There is no air consumption due to the level detection system : an
inductive sensor detects the level of condensation and thus controls
the opening of the electric bleed valve. A low level of condensation
is also detected in order to close the electric bleed valve and to prevent
compressed air from being wasted.
- This type of purge valve does not require any maintenance. The
purge valve does not require the use of the metallic intake filter that
is usually installed on electronic purge valves to protect the solenoid
valve. The solenoid valve will not be damaged.
- Condensate treatment is made easier because it is not evacuated by
pressure, which enables easy separation of the water and oil stages.
Fig. 12
1
2
3
1 - Condensation intake
2 - Capacitive sensor
3 - Receiver
3 - Technical features
Maximum capacity of the compressor
Working pressure
Operating pressure
Electric power supply
AC socket in the compressor electric cabinet.
B -Advanced filtration to the compression
air inlet (Fig. 13a and 13b)
1 - Description
This system is equipped for "high efficiency" air filtration in order
to improve the quality of the air intake and to preserve the
compressor's oil and internal filter components.
This option is particularly useful in very dusty surroundings.
11/2008
Page 14
4
5
6
4 - Main duct
5 - Electric valve
6 - Membrane
CP 175 to 250
:
3178 cfm
:
11.6/232 PSI
:
+ 33.8/ + 140°F
:
115V/24V
2 - Option overview
- This option is used as a replacement for the standard filter
- Certain atmospheric particles are smaller than 78
threshold for traditional paper cartridge filters. The filter increases
filtration effectiveness by eliminating 99.97% of particles that
are larger than or equal to 118
- The quality of the air intake by a compressor is essential. Low
quality air creates the following :
• Quick pollution of the oil thus an increase in draining cycles.
• Binding of the air / oil separator before 4000 hours thus an
increase in maintenance cycles and operation costs.
• Pollution increases the elements that filter into the air and oil,
speeding up the damage to the mechanical components of the
compressor, screw element,...
Filters in compliance with standard ISO 5011/2000.
- Exceptional filter longevity, from 18 months to 3 years of
continuous service (24 hours a day, 7 days a week), which is a
little more than 10,000 hours of operation of the compressor under
normal conditions.
- Installation of the filter(s), depending on the model, outside the
compressor, for intake of fresh air, hence resulting in a lower oil
temperature and more efficient compression (Fig. 13a and 13b).
x
CPF 175
CPVS 200
CPF 200
CPVS 250
Fig. 13a
Cartridge
Fig. 13b
in, a limiting
10-6
10-6
in.
Extraction duct
VORTEX pre-filter
Air filter
y
x
y
98,58
16,9
111,8
16,9
Chicago Pneumatic Compressors
62 305 799 65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpf 200Cpvs 200Cpvs 250

Table of Contents