Chapter 7 - Maintenance; A - Oil Level And Change - Chicago Pneumatic CPF 175 Instruction Manual

Cp compressor
Hide thumbs Also See for CPF 175:
Table of Contents

Advertisement

Chapter 7 - Maintenance

The maintenance period is limited to several essential operations.
It is strongly recommended that the power supply be cut off during
any adjustment or repair.
Parts
Daily
Draining cock
Oil level
Air filter
Oil tank,
Oil change
Suction housing
Oil return pipe
Oil separator
Oil filter
Oil cooler
Final coolant
Valve at minimum
pressure
Motor for
CPF
175-200
Motor for
CPVS
200-250
Electric cabinet
Safety temperature
test
Coupling
NOTE : maintenance kits are available (see spare parts list).

A - Oil level and change

(see fig. 21 and B chapter 1)
Caution :
Never mix oils of different makes and types. To maintain opti-
mum oil quality, drain all the drainage points of the compressor.
The spent oil that remains in the compressor may contaminate the
oil system.
It is strongly recommended to use Chicago Pneumatic
Compressors oil.
Chicago Pneumatic Compressors
62 305 799 65
Operations to be carried out
Every
Every
500 h
150 h
X
X
X
X
X
X
The summary on the CP Compressor instrument panel shows at a
glance the type and periodicity of operations to be carried out for the
compressor to function correctly.
Every
Every
2 000 h (*)
4 000 h
Service A
X
X
lubrication
X
lubrication
X
X
X
X
X
(*) or at least every year
The recommended oil used for the first compressor fill up is a
mineral oil with the following properties :
- viscosity: 40 cSt at 104°F
- viscosity index: 90 minimum
- antioxidant additives
- anti-rust additives
- anti-foam additives
Every
Every
6 000 h
12 000 h
Service B
Service C
Drain the condensates
from the cold oil circuit
(Chapter 7 - G)
Check and top up if
necessary
(Chapter 7 - A)
Replace the filter
Oil change, oil refill
with recommended oil
(Chapter 7 - A)
Control
Renovation of the
cleaning
Overhaul kit housing. Use the
suction housing kit
Check the cleanliness of
Overhaul
the oil return pipe and
Kits
the state of the seal
(Chapter 7 - F)
Change the part
X
according to the
instrument panel indication
(Chapter 7 - E)
Filter change
Blowing of cooling
elements
Cleaning (Chap. 7 - D)
Control
Exchange the accessories
cleaning
Overhaul
supplied with the
kits
maintenance kit
For motors fitted with
grease fitting, use
2901033813
KLUBERQUIET
BQH72-102
(16 g per grease fitting)
For motors fitted with
grease, use Polyrex
2908851410
EM-ESSO (16 g per
ase fitting)
(16 g per grease fitting)
Retighten power cable
connections.
Check operation
(Chapter 7 - H)
Check coupling condition
Observations
11/2008
Page 21