Button Operation
Press To Set Dispensing Period
1,2,3...12 month (12 Modes)
MODE
LOCK
Press for 2 seconds to unlock (
)
Power ON/OFF
POWER
Hold to power unit on or off
Press To Select Grease Capacity
(60/125/250ml)
TEST
TEST Mode
ON : Press for 2 seconds
OFF : Short press of button
(Will stop after completion of ongoing cycle)
Vibration Detection Mode
Reset to default setting when the
RESET
(Refer to the Installation Guideline Step 7)
unit malfunctions and/or after
+
Hold the Power button and then
changing the Service Pack
press the Mode button
LCD Display
Dispensing period setting
Test Mode (PURGE Mode)
MONTH
Number of days remaining
Number of days passed since the
until dispensing period ends
end of dispensing period
,
will also be displayed.
Automatic Lock Out mode
Number of days operation has
been on hold
will also be displayed.
Grease pouch capacity
60/125/250
Maximum runtime has been
Low battery power
reached
,
will also be displayed.
Excessive backpressure /
Operation on hold
Signal lamp blinks periodically
when battery power is low,
Red
excessive backpressure exists, or
LED
Empty grease level
if grease level is empty
Mounting Methods
Single Point Installation
Direct Mount or Remote Installation using Extension Tubing
Direct mount is always preferable. For applications not allowing
any direct mounts, remotely mount the unit using appropriate
accessories and keep the distance from the lube point as short as
possible.
For remote installation using a tube, use a 6mm O.D. (1/4") tubing
pre-filled with the same or compatible grease as the grease
contained in the unit.
Multi-Point Installation
Multi-Point Remote Installation using Progressive Divider Block
Ensure the break-off pressure is below the average operating
pressure of 30kgf/cm
2
(425psi).
Warning
Do not block any ports on divider block and use a divider
block corresponding to the number of ports required for multi-
point installation.
(Ex. HU-3RS for 3 lube points, HU-5RS for 5 lube points)
For more information, please refer to the Multi-Point Remote
Installation user.
(Reference: Website > Service Menu > Technical Information)
Precautions
Wiring : Ensure the wire to be keep away from vibration detector.
Regular Inspection : Keep the position of the vibration detector vertical. When performing periodic
maintenance checks, re-run Vibration Detection Mode to ensure vibration is correctly being detected.
Adjust position of sensor box and sensitivity as needed.
Replacement Service Pack after the Recommended Use Time : If
appears on the
LCD after 2 years (250ml : 1 year and 6 months) from the installation date, replace the service pack
immediately even if the grease remains in the pouch. (Dispensing failures may occur after long periods of
time due to grease hardening and/or drops in battery voltage.)
Shelf life and Warranty Product Warranty is limited to original defects in material and
workmanship and will not cover any collateral damage due to mishandling, abuse and /or any
other inappropriate use of this product. Warranty period is 1 year from the date of purchase.
Rev.00
/
The World Leader of Automatic Lubrication
Pulsarlube USA, Inc.
1480 Howard Street, Elk Grove Village, IL 60007, USA
TEL : 1-847-593-5300 FAX : 1-847-593-5303 www.pulsarlube.com / info@pulsarlube.com
User Manual
Mi
Series
( 60ml&125ml& 250ml )

Advertisement

loading
Need help?

Need help?

Do you have a question about the MI60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pulsarlube MI60

  • Page 1 1480 Howard Street, Elk Grove Village, IL 60007, USA excessive backpressure exists, or workmanship and will not cover any collateral damage due to mishandling, abuse and /or any TEL : 1-847-593-5300 FAX : 1-847-593-5303 www.pulsarlube.com / info@pulsarlube.com Empty grease level if grease level is empty...
  • Page 2 How To Adjust Sensor Level LCD Display During Proper Synchronization Product Details Installation Guidelines How To Replace Service Pack Open the yellow cap of sensor box. When the equipment is in operation, Housing the clock icon will be displayed. Check the grease pouch capacity and the service pack items (battery pack, grease pouch, dust cover &...

This manual is also suitable for:

Mi125Mi250