Analog Input Functions and Operating Procedures
2-6-3

Mean Value Processing

Address
CS1W-AD161
D(m+2)
---
D(m+3)
Input 1
D(m+4)
Input 2
D(m+5)
Input 3
D(m+6)
Input 4
D(m+7)
Input 5
D(m+8)
Input 6
D(m+9)
Input 7
D(m+10)
Input 8
D(m+11)
Input 9
D(m+12)
Input 10
D(m+13)
Input 11
D(m+14)
Input 12
D(m+15)
Input 13
D(m+16)
Input 14
D(m+17)
Input 15
D(m+18)
Input 16
The Analog Input Unit can compute the mean value of the conversion values
of analog inputs that have been previously sampled. Mean value processing
involves an operational mean value in the history buffers, so it has no effect on
the data refresh cycle. (The number of history buffers that can be set to use
mean value processing is 2, 4, 8, 16, 32, or 64.)
Conversion data
When "n" number of history buffers are being used, the first conversion data
will be stored for all "n" number of history buffers immediately data conversion
has begun or after a disconnection is restored.
When mean value processing is used together with the peak value hold func-
tion, the mean value will be held.
Specify whether or not to use mean value processing and the number of his-
tory buffers to be used for mean value processing.
CS1W-AD081-V1
CS1W-AD041-V1
Input 1
Input 1
Input 2
Input 2
Input 3
Input 3
Input 4
Input 4
Input 5
Cannot be used.
Input 6
Input 7
Input 8
Cannot be used.
For the DM word addresses, m = D2000 + (unit number x 100)
Note After making the DM settings from a Programming Device, it will be necessary
to either turn the power to the PLC OFF and ON, or turn ON the Special I/O
Buffer 1
Buffer 2
Buffer 3
(Mean value
processing)
Buffer 4
Buffer n
(Discarded)
0000: Mean value processing with 2 buffers
0001: No mean value processing
0002: Mean value processing with 4 buffers
0003: Mean value processing with 8 buffers
0004: Mean value processing with 16 buffers
0005: Mean value processing with 32 buffers
0006: Mean value processing with 64 buffers
Section 2-6
Conversion value
(Values stored in
CIO words n+1 to
n+8)
Set value
55