3.3

SYSTEM CONFIGURATIONS

After the load cell shipping/restraining bolt has been removed and the dynamometer has been
earth grounded, the unit is ready for connection to the appropriate readout instrument and power
supply.
3.3.1
M
T
anual
The dynamometer can be set up as a manual test system for quick pass/fail testing on the production
line or at incoming inspection. A typical manual test system will consist of a Magtrol Hysteresis
Dynamometer used in conjunction with a Magtrol 6200 Open-Loop Controller.
Note:
The following diagram illustrates the required cable sets and connections for a manual test system
setup.
S
eST
ySTeMS
Magtrol's Single or Three-Phase Power Analyzer may be included
as an option.
HD / ED
DYNAMOMETER
o----------
o----
1
o----------
2 Pin Dynamometer Brake Cable
PN88M070-0150 (included with dynamometer)
14 Pin/14 Pin Instrument Cable
Figure 3–6 Dynamometer with 6200 Controller
Chapter 3 – Installation/Configuration
6200 CONTROLLER
PN88M007-0150 (included with dynamometer)
31