Table 2-1. Data Recording Parameter Behavior
Before
Power
Failure
1
Data logging will
Receiver data
not resume when
logged to file
power is restored.
specified.
2
Data logging will
Receiver data
not resume when
logged to
power is restored.
default file.
3
No file will open
File
with this name.
specified;
Data logging will
receiver data
not start when
logging not
power is restored.
started.
4
Data logging will
No file
not start when
specified;
power is restored.
receiver data
logging off.
Also, if Always is enabled, your receiver will automatically
start logging data (to a newly created or an existing file) in the
following three cases:
• After turning on the receiver using the Power key.
• After resetting the receiver (using PC-CDU or pressing the
Reset key).
• After taking the receiver out of Sleep Mode.
1-866-4TOPCON
Enabled Radio Button Results
Off
Receiver will
resume data
logging to the
same file when
power is restored.
A new log file
will open when
power is restored
and data will log
to this file.
No file will open
with this name.
Data logging will
not start when
power is restored.
Data logging will
not start when
power is restored.
MINTER Configuration
On
Always
Receiver will
resume data
logging to the same
file when power is
restored.
A new log file will
open when power
is restored and data
will log to this file.
A log file with this
name will open and
data logging will
start after power is
restored.
A log file with a
default name will
open and data
logging will start
after power is
restored.
www.topconpositioning.com