Limit Operating Conditions:
200 A permanently to 1 kHz
Derating above 3 kHz: 200 A x (1/0.333 F), F in kHz
Crest Factor:
3 @ 200 Arms with an error (due to CF) of 4%
Working Voltage: 600 Vrms
Common Mode Voltage: 600 Vrms
Influence of Adjacent Conductor:
< 15 mA/A at 50 Hz
Influence of DC (< 20 A) on AC signal:
< 5%
Influence of Conductor Position in Jaw:
0.5% of mA output @ 50/60 Hz
Influence of Load:
< 3% of mA output from 40 Hz to 1 kHz
< 12% of mA output from 1 kHz to 10 kHz
Influence of Temperature:
≤ 150 ppm/°K, or 0.15% of mA output per 10°K
Influence of Humidity (10 - 90% RH):
≤ 0.2% of mA output per 10°K @ 18°C to 28°C
MECHANICAL SPECIFICATIONS
Operating Temperature:
14° to 131°F (-10° to +55°C)
Storage Temperature:
-40° to 158°F (-40° to +70°C)
Operating Relative Humidity:
10-35°C 85% RH (without roll-off above 35°C)
Maximum Cable Diameter:
One Ø 0.78" (20 mm), bus bar 20 x 5 mm
Case Protection:
IP 40 (IEC 529)
Drop Test:
Test per IEC 68-2-32: 1.0 m drop on 38 mm of
Oak on concrete.
Mechanical Shock:
Test per IEC 68-2-27
Vibration:
Test per IEC 68-2-6
Dimensions:
5.47 x 2.00 x 1.18" (139 x 51 x 30 mm)
Weight: 180 g (6.5 oz)
Polycarbonate Material:
Jaws: Polycarbonate with 10% fiberglass charge,
Red UL 94 V0
Case: Polycarbonate 920A Gray
Opening Operations - Life: > 50,000
Output:
MN210: Two standard safety banana jacks (4 mm)
MN211: Double/reinforced insulated 5 ft. (1.5 m)
lead with safety 4mm banana plug

SAFETY SPECIFICATIONS

Electrical:
Double insulation or reinforced insulation between
the primary or secondary and the outer case of the
handle conforms to IEC 1010-2-32.
Common Mode Voltage:
600 V Category III, Pollution Degree 2
Dielectric Strength:
5550 V, 50/60 Hz between primary, secondary
and the outer case of the handle
Electromagnetic Compatibility:
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge
IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60 Hz IEC 1000-4-8

ORDERING INFORMATION

AC Current Probe MN210 ................. Cat #2115.72
AC Current Probe MN211 ................. Cat #2115.73
Both models include a user manual and a
product warranty and registration card.
Accessories:
Leads, set of 2, 5 ft safety (1000V) ..... Cat #2111.29
Banana plug adapter
(to nonrecessed plug) ........................ Cat #1017.45
E192383

Advertisement

loading

This manual is also suitable for:

Mn211