Download Print this page

Safety Specifications; Ordering Information - AEMC MD314 User Manual

Ac current probe

Advertisement

Common Mode Voltage:
600Vrms
Influence of Adjacent Parallel Conductor:
< 30mA/A at 50Hz
Influence of Conductor in Jaw Opening:
± 1.5%  0.1A
MECHANICAL SPECIFICATIONS
Operating Temperature:
-5° to 122°F (-15° to 50°C)
Storage Temperature:
-40° to 185°F (-40° to 85°C)
Influence of Temperature:
< 0.1% per 10°K
Jaw Opening:
1.3" (33mm)
Maximum Conductor Size:
1.18" (30mm)
Maximum Bus Bar Size:
2.48 x 0.20" (63 x 5mm)
Envelope Protection:
IP 20 (IEC 529)
Drop Test:
1.5m (IEC 68-2-32)
Mechanical Shock:
100g (IEC 68-2-27)
Vibration:
10/55/10Hz, 0.15mm (IEC 68-2-6)
Polycarbonate Material:
Handles: 10% fiberglass charged
polycarbonate UL 94 V0
Dimensions:
2.6 x 7.68 x 1.34" (66 x 195 x 34mm)
Weight:
14.82 oz (420g)
Colors:
Dark gray handles
Output:
Double insulated 5ft (1.5m) lead with safety
banana plugs

SAFETY SPECIFICATIONS

Electrical:
Double insulation or reinforced insulation between
the primary or secondary and the outer case of the
handle upon IEC 1010-2-032.
600V CAT III, Pollution Degree 2
Electromagnetic Compatibility:
EN 50081-1 Class B
EN 50082-2 Electrostatic discharge
IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60Hz IEC 1000-4-8

ORDERING INFORMATION

Current Probe MD314 .................... Cat. #2110.75
Accessories:
Banana plug adapter
(to non-recessed plug) .................... Cat. #1017.45

Advertisement

loading