Download Print this page

AEMC MN113 User Manual

Ac current probe

Advertisement

Quick Links

AC Current Probe
Model MN113
User Manual
DESCRIPTION
The MN113 (Catalog #2114.99) is a high accuracy voltage output current probe for tight areas such as
crowded wiring. Extends DMM AC measurements to 10A
jack.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the
instrument.
• Read the instruction manual completely and follow all the safety information before attempting to
use or service this instrument.
• Use caution on any circuit: Potentially high voltages and currents may be present and may pose a
shock hazard.
• Read the Safety Specifications section prior to using the current probe. Never exceed the
maximum voltage ratings given.
• Safety is the responsibility of the operator.
• ALWAYS connect the current probe to the display device before clamping the probe onto the
sample being tested.
• ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use. Replace
any defective parts immediately.
• NEVER use the current probe on electrical conductors rated above 600V in overvoltage. Use
extreme caution when clamping around bare conductors or bus bars.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation.
Use only specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before
using the instrument.
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your
distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the
carrier and notify your distributor at once, giving a detailed description of any damage.
PACKAGING
The AC Current Probe MN113 is shipped with this instruction manual and a product warranty and
registration card.
INSTRUMENT COMPATIBILITY
The Model MN113 is compatible with any voltmeter, multimeter, or other voltage measuring instruments
with an input impedance greater than 100 KΩ. To achieve the stated accuracy, use the MN113 with an
voltmeter having an accuracy of 0.75% or better.
. The Model MN113 offers a 4mm banana
AC

Advertisement

loading

Summary of Contents for AEMC MN113

  • Page 1 The Model MN113 is compatible with any voltmeter, multimeter, or other voltage measuring instruments with an input impedance greater than 100 KΩ. To achieve the stated accuracy, use the MN113 with an voltmeter having an accuracy of 0.75% or better.
  • Page 2 =0.47" max. (12 mm) Black 0.87" 1.26" (22 mm) (32 mm) ELECTRICAL SPECIFICATIONS Phase shift: Current Range: 100 mA to 10 A ≤ 8 ° 1 mA to 10 A AC Continuous duty cycle (*Reference conditions: 23°C ±3°K, 20 to 85% RH, 48 to 65 Hz, external magnetic Output Signal: field <40 A/m, no DC component, no...
  • Page 3 Operating Temperature: ORDERING INFORMATION - 13° to 122°F (- 25° to 50°C) AC Current Probe Storage Temperature: Model MN113 ....Cat # 2114.99 - 40° to 176°F (- 40° to 80°C) Accessories: Pair, Current Leads Influence of Temperature: (39” color-coded) ..Cat # 100.361 <...
  • Page 4 Making Measurements with the AC Current Probe Model MN113 • Connect the terminals to the 2 V range of your DMM or instrument. The MN113 has a ratio of 10:1. This means that for 10 A AC in the conductor around which the probe is clamped, 1 V AC will come out of the probe leads to your DMM or instrument.