Locking The Reset Pin - Radionics D7212 Operation And Installation Manual

Control / communicator
Table of Contents

Advertisement

Existing reports transmitted with Reset Pin locked down: Any reports that are in the
panel's report buffer when you lock down the Reset Pin, will be transmitted. However, no
new reports can be created with the pin locked down.
To prevent buffered reports from being transmitted, momentarily close the Reset Pin, wait
for the buzzer to stop sounding, and then lock the pin down to prevent new reports from
being generated.
Locking Reset Speeds Programming: If you have supervised command centers or other
supervised devices connected to the Data Bus (terminals 30 and 31), locking the Reset
Pin will speed communication between the panel and the D5200.
On-board relays (terminals 6, 7, and 8) and off-board relays, deactivate when the panel is
reset. There is power at terminal 8 when the relay is deactivated. Activation interrupts
power at that terminal. The relays remain deactivated while the Reset Pin is locked in the
disable position.
You can program the panel while it is locked in the disable position with either the D5200 or
D5300 (RAM II) programmers. If you place the reset pin in the disable position with one or
more areas disarmed, there must be an entry in the Answer Disarmed
program item to use RAM II.
If you place the reset pin in the
disable position when all areas are
armed, there must be an entry in the
Answer Armed program item. See
RAM Parameters in the
D7212 Program Entry Guide
(74-06915-000).
Releasing the reset pin from the
closed position resets the panel.
The panel resets all its timers,
counters, indexes, and buffers.
Changes to some program
NCI
parameters require a reset before
142,
they become effective: Radionics
347, 353
recommends that you reset the
panel after changing program
parameters with the D5200 programmer.
The D5300 (RAM II) programmer prompts you
for a "RESET BYE" when a program change requires that the panel be reset.
Lock the Reset Pin Now
Locking the pin in the disable position allows you to power up the panel and charge the
battery as you install the detection devices and command centers. Lock the pin down now.
74-06913-000-B 2/96
D7212 Operation & Installation Manual
Page 15
Operation Monitor
Pulses When Normal
Flickers When Ringing
GRN
Reset Pin
Disable All Except Battery
Charging And Local Programming
SDI DEVICE WIRING
32
RED
POWER +
31
YELLOW
DATA BUS A
GREEN
DATA BUS B
30
BLACK
COMMON -
29
Figure 3: Reset Pin
RESET PIN
LOCKED (CLOSED)
RESET PIN
NORMAL (OPEN)
© 1993-1996 Radionics