2. Disconnect the Grounding Cable [1].
• 2 Connectors [2]
• 1 Screw [3]
• 1 Wire Saddle [4]
3. Open the ADF.
4. Remove the ADF [1].
CAUTION:
When holding this equipment, be careful not to touch the Platen roller [3].
• 2 Screws [2]

Actions after Reinstalling the ADF

1. Adjusting the
Height."Adjusting the Height" on page 70
2. Adjusting the Perpendicularity
3. Adjusting the Reading
4. Adjusting the
Magnification"Adjusting the Magnification" on page 79
5. Adjusting the Image Position (Main Scanning
on page 80
6. Adjusting the Image Position (Sub Scanning
page 81
7. Adjusting the White Level
2x
1x
[3]
2x
"Adjusting the Perpendicularity" on page 74
Position"Adjusting the Reading Position" on page 78
Direction)"Adjusting the Image Position (Main Scanning Direction)"
Direction)"Adjusting the Image Position (Sub Scanning Direction)" on
"Adjusting the White Level" on page 82
4. Parts Replacement and Cleaning
[2]
[1]
[3]
[4]