UL1604 Conditions of Acceptability and Handling Cautions:
1. Power, input and output (I/O) wiring must be in accordance with Class I, Divi-
sion 2 wiring methods - Article 501- 4(b) of the National Electrical Code,
NFPA 70 within the United States, and in accordance with Section 18-152 of
the Canadian Electrical Code for units installed within Canada.
2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous
Locations.
3. WARNING: Explosion hazard - substitution of components may impair suit-
ability for Class I, Division 2.
4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF
before replacing or wiring modules.
5. WARNING: Explosion hazard - do not disconnect equipment unless power has
been switched OFF, or the area is known to be non-hazardous.

CE Marking Notes

The GP2401-TC41-24V is CE marked products that conform to EMC directives
EN55011 Class A and EN61000-6-2.
The GP2501-TC11
ucts that conform to EMC directives and the Low-voltage directive EN55011
Class A, EN61000-3-2, EN61000-3-3, EN61000-6-2 and EN60950.
For detailed CE marking information, please contact your local GP distributor.
*1 The products on which Revision "3" is marked conform to the standard requirements.
to section "Revision Version" (page 13).
<Cautions>
• The GP must be used as a built-in component of an end-use product.
• The GP units must be used indoors only.
• This unit should be installed in the front face of a metal panel.
• If this unit is installed so as to cool itself naturally, be sure to install it in a
vertical panel. Also, be sure that the GP unit is mounted at least 100 mm away
from any adjacent structures or equipment. If these requirements are not met,
the heat generated by the GP unit's internal components may cause the unit to
fail to meet the standard requirements.
• Make sure to set up a switch to turn off the power to the GP in an accessible
position on the end-use product that the GP unit is built-in. Make sure to
consider the current and voltage when selecting the switch.
• Make sure that the frame of the product to which the GP unit is built-in con-
forms to EN60950 standard requirements.
12
*1
*1
, GP2501-SC11
and GP2601-TC11
For more information on how to determine the revision version, refer
*1
are CE marked prod-
GP-2401/2501/2601 Series User Manual