2 Introduction
Expanded functions provided by the OPX-2A
By using the OPX-2A you can expand the specifications and functions as follows.
• Specification
Rotating speed
Rotating speed range : 80 to 4000 r/min
• Function
Function
Display of various
items
Multi-speed setting
Torque limit
Setting of various
functions
Assignment of I/O
signals
Warning output
Digital/analog input
switching
Test function
Copy function
−4−
: The rotating speed can be digitally set in units of 1 r/min.
Description
•
Rotating speed
•
Transfer speed
•
I/O (input/output signals) status
•
Load factor
•
Alarm code
•
Warning code
Up to eight sets of operation data can be set,
and the rotating speed, torque limit,
acceleration time and deceleration time are
set for each data set.
Set the limit value of output torque to each
operation data.
Gear ratio
•
•
Speed increasing ratio
•
Conveyor gear ratio
Conveyor speed increasing ratio
•
Rotating speed attainment band
•
Motor direction selection
•
Change the assignment of I/O signals
Set the warnings that are output before the
corresponding alarms generate (warning
functions).
The rotating speed can be set either as
digital or analog.
I/O test
•
Test operation (JOG operation)
•
Data copy
•
Data initialize
•
Setting mode
Monitor mode
Data mode
Parameter
mode
Test mode
Copy mode