Orientalmotor OPX-2A Operating Manual page 17

Data setter ble series
Hide thumbs Also See for OPX-2A:
Table of Contents

Advertisement

Present warning
When an warning generates, the WNG
you can change the display to the warning code mode to check the details of the warning . For the
operating procedure, refer to "6.2 Operation in the monitor mode" on p.14.
You can also check or clear warning records.
• Warning generation conditions
Description
Overload
The motor received a load exceeding the overload detection level (load factor) set
warning
by the warning parameter [APP-2].
The FWD input or REV input was ON when the test mode was ended after
performing test (JOG) operation in the test mode.
Operation
prohibited
The FWD input or REV input was ON when the assignment of an input terminal
was changed using the corresponding applicable I/O parameter.
∗ When the overload warning function is enabled. (For the method to set the function, see p.29.)
• Warning code list
Code
Warning name
30
Overload
6C
Operation prohibited
Do not turn off the driver power while warning records are being cleared (= while the
Note
display is blinking). Doing so may damage the data.
• How to reset an warning
Even when a warning generates, the motor and driver continue to operate without stopping. Once the
cause of the warning is removed, the warning output will turn OFF automatically.
If an operation prohibited warning is generated, an operation command by the FWD input or REV input
will not take effect and the motor will not operate.
The operation prohibited warning will automatically be cleared by turning OFF the operation input.
• How to check a warning record
You can check up to ten most recent warnings, starting from the latest one.
1.
While a warning is displayed, press the
The latest warning is displayed.
2.
Press the
The second latest warning is displayed.
3.
Every time the
keys to select the warning record you want to check.
• How to clear all warning records
You can clear all warning records at once.
1.
While a warning is displayed, press the
2.
Press the
3.
Press the
All warning records are cleared.
You can also clear warning records by turning off the driver power.
Note
LED (orange) on the OPX-2A is lit. When this LED is lit,
Motor operation
Operation
Stop
key.
key is pressed, the next older warning will be displayed. Use the
key and select the warning record clear screen.
key.
Condition
key to move to the lower level.
key to move to the lower level.
6 Monitor mode
−17−

Advertisement

Table of Contents
loading

Related Products for Orientalmotor OPX-2A

Table of Contents