8 Parameter mode
• Functions expandable using the OPX-2A
Speed setting selection input (M0, M1, M2)
Select operation data by a combination of ON/OFF statuses of M0 to M2 inputs.
Set the operation data in the data mode (P.19).
EXT-ERROR input (External error input)
The motor stops when the external error signal is input. Turn the signal ON to operate the motor
(normally closed).
MOVE output (Motor running output)
This signal is output while motor operate.
VA output (Speed attainment output)
This signal is output when the difference between the set rotating speed and actual rotating speed of the
motor becomes equal to or less than the value set by the rotating speed attainment band parameter
[APP-0-06].
ALARM-OUT2 output
When the overload detection level is exceeded, the ALARM-OUT2 output will turn OFF. Once the load
drops to below the detection level, the output will return to the ON status.
The detection level can be set using the "overload warning detection level" parameter [APP-2-00].
Once the overload protection function is actuated the ALARM-OUT2 output will always turn OFF.
WNG output (Warning output)
If a warning generates, the WNG output will turn ON. Once the warning is reset, the WNG output return
to OFF.
For the types of warnings, refer to p.17.
TLC output (Torque limit output)
This signal is output when the motor output torque reaches the limit value.
−28−