I/O parameters
You can change the assignments of I/O signal terminals using I/O parameters.
Driver terminal
to be assigned
Signal name
a signal
FWD
REV
STOP-MODE
M0
M1
M2
Input signal
terminal
ALARM-RESET
X0 to X6
EXT-ERROR
MB-FREE
TH
SPEED-OUT
ALARM-OUT1
MOVE output
VA output
Output signal
terminal
Y0+, Y0−
Y1+, Y1−
ALARM-OUT2
WNG output
TLC output
Name
Forward input
Reverse input
Stop mode selection
input
Speed setting selection
input
Alarm reset input
External error input
Electromagnetic brake
release input
Regeneration resistor
thermal input
SPEED-OUT output
ALARM-OUT1 output
Motor running output
Speed attainment
output
ALARM-OUT2 output
Warning output
Torque limit output
The motor will rotate in the clockwise (CW)
direction.
The motor will rotate in the counter clockwise
(CCW) direction.
Select either instantaneous stop or deceleration
stop.
Select operation data by a combination of
ON/OFF statuses of M0 to M2 inputs.
(see P.20.)
Alarms are reset when the driver's protective
function is actuated.
The motor stops when the external error signal
is input (normally closed). Turn the signal ON to
operate the motor (normally closed).
When the motor stops, the electromagnetic
brake is released and the motor shaft becomes
free.
If the regeneration unit is connected, connect
the thermostat outputs of the regeneration unit
(normally closed).
30 pulses are output per each revolution of the
motor output shaft. (In the FBLⅡ compatible
mode, 12 pulses are output per revolution.)
This signal is output when an alarm generates
(normally closed).
This signal is output while motor operate
(operation input is ON).
This signal is output when the motor rotating
speed reaches the set value. (including the
rotating speed attainment band).
If the overload warning function is enabled, this
signal is output when the overload warning
detection level is exceeded. Even when the
overload warning function is disabled, this
signal is still output when an overload alarm
generates (normally closed).
This signal is output when the overload warning
function actuates and a warning generates.
To reset the warning, the WNG output will
automatically return to OFF.
This signal is output when the motor output
torque reaches the limit value.
∗ These functions will become effective using the OPX-2A.