Download Print this page

Precautions For Correct Use; Precautions For Safe Use - Omron FH-SM05R Instruction Sheet

Image sensor for fh - 5 megapixel digital camera
Hide thumbs Also See for FH-SM05R:

Advertisement

Model
FH-SM05R/SC05R
Image Sensor for FH - 5 Megapixel Digital Camera
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
TRACEABILITY INFORMATION:
Importer in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
NOTICE:
This product meets CISPR11 class A. The intended use of this product is in an
industrial environment only.
© OMRON Corporation
2015
All Rights Reserved.
PRECAUTIONS ON SAFETY
Meaning of Alert Symbols
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury,
WARNING
or may result in serious injury or death. Additionally
there may be significant property damage.
Alert statements
WARNING
This product is not designed or rated for ensuring safety
of persons. Do not use it for such purposes.

PRECAUTIONS FOR SAFE USE

Be sure to respect following items for safety.
・ Tighten all screws securely during installation.
・ Do not connect the Sensor to the products other than the dedicated
camera cable (FZ-VS□□), controller (FH), Camera-mount
Lighting controller (FL-TCC1 and FLV-TCC□), extension unit
(FZ-VSJ). If the Sensor is connected to non-dedicated products and
turned the power on, the devices may be damaged and be heated to a
high temperature.Do not put an impossible stress on the camera
cable when you set it up. The cable is disconnected, and it becomes
impossible might do a normal measurement.
・ If you suspect an error or malfunction, stop using the Controller
immediately, turn OFF the power supply, and consult your OMRON
representative.
・ Do not try to disassemble, repair, or modify the product.
・ Be sure to dispose of the product as industrial waste.
・ Do not put an impossible stress on the camera cable when you set it
up. The cable is disconnected, and it becomes impossible might do a
normal measurement.

PRECAUTIONS FOR CORRECT USE

Please observe the following precautions to prevent failure to operate,
malfunction, or undesirable effect.
1. Installation and storage of the product
Do not install in the following locations.
・ Locations where the ambient temperature exceeds the rated
temperature range.
・ Locations subject to sudden temperature changes (where
condensation will form).
・ Locations where there are corrosive or flammable gases.
・ Locations where there is dust, salt, or iron powder.
・ Locations where the device will be subject to direct vibration or
shock.
・ Locations where there is strong scattered light.
・ Locations exposed to direct sunlight
・ Locations where there is splashing of water, oil, or chemicals.
・ Locations where there is a strong electrical or magnetic field.
・ Locations close to high-voltage devices and/or power devices
2. Cables
・ When connecting or disconnecting the camera cable or
Camera-mount Lighting controller cable, be sure to turn off the
controller unit.
・ Do not use the camera cable exceeding the specified length.
・ Up to three camera cables can be connected using the extension unit
FZ-VSJ. Be sure to use the recommended camera cable with
FZ-VSJ.
・ When connecting the camera cable, tighten the cable with the fixing
screw with the recommended torque (0.15 N ・ m). Applying excessive
force to the camera connector may cause failure of the product.
・ Use the ferrite core equivalent to ZCAT2035-0930A (manufactured
by TDK) at the controller side of the camera cable.(except for FH-L
series)
・ The camera cable FZ-VS□□ has polarity. Be sure to connect the
side with the name plate on it to the controller. Be sure to connect
the side with the name plate on it to the controller.
3. Mounting
The camera case is connected to the 0 V line of the internal circuit.
Observe the following precautions to prevent noise from entering
the camera.
・ Do not ground the camera unit.
・ Be sure to use a base for installation. When mounting a base, engage
it with the screw (M4) with the recommended torque (1.2 N ・ m).
4. Beam
・ The beam center may vary for each camera. Be sure to confirm the
center position of the image using the monitor before mounting. In
the nature of the materials used, the beam center of this product
may change for the number of pixels due to changes in ambient
temperature.
5. Maintenance
・ Avoid using thinner, alcohol, benzene, acetone or kerosene to clean
the product.
・ If there is large dirt or dust attached to the imaging element, blow
them off with blower brush (for camera lens). Do not use your breath
to blow the dust off.
・ When the lens is not mounted, be sure to attach the C-mount cap on
the lens mount. If dirt or dust is attached to the image elements,
false detection or failure may occur.
・ Be sure to attach a connector cap on unused connectors at the back
of the camera. Removing the connector cap may cause a foreign
material entering in the camera, causing false operation or failure.
・ Do not connect devices to the extension connector other than the
dedicated ones (FL-TCC1 or FLV-TCC□).
6. Imaging element
・ In the nature of imaging element, lines may appear in images due to
measurement conditions or sensitivities. This does not indicated a
malfunction. Although there may be multiple faulty pixels, this does
not indicate a malfunction. If these conditions affect measurement or
inspection, use the CCD camera.
Ratings / Performance
General specifications
Model
FH-SM05R
Item
FH-SC05R
1.2 W max. (13 VDC)
Power consumption
Vibration
10 to 150Hz: half-amplitude: 0.35mm:(maximum acceleration: 50m/s
resistance
10 times for 8 minutes each in 3 directions
Shock resistance 150m/s
; 3 times each in 6 directions
Shock resistance
2
Operating: 0 to 40 ℃(with no icing nor condensation)
Ambient
Storage: -25 to 65 ℃ (with no icing nor condensation)
Temperature
Operating and storage: 35% to 85%
Ambient
(with no condensation)
humidity
Ambient
No corrosive gases
environment
Degree of
IEC60529 IP40 (in-panel)
protection
Center positional
X, Y : ±0.31mm
accuracy of
∂x, ∂y : ±2.1°
optical axis
Case: Aluminum
Materials
Camera base: PC/ABS
Mount screw: brass
Weight
Approx. 60 g (including base)
Accessories
Instruction Sheet (this sheet)
Using FZ-VS4/VSL4: 15 m max.
Cable length
Using a dedicated product other than
FZ-VS4/VSL4: 10 m max.
●Performance specifications
Model
FH-SC05R
FH-SM05R
Item
1/2.5-inch monochrome
Picture element
1/2.5-inch color CMOS
CMOS
Effective pixels
2592(H) × 1944V)
Pixel size
2.2(μm) × 2.2(μm)
Scanning method
Progressive
Shutter
Rolling shutter
Frame rate
14fps
Synchronization method
Internal
Video output
Digital (8 bits)
Gain
0 to +20 dB
Exposure time
500us∼100,000us (by 50us unit)
Lens mounting
C mount(Recommended: 3Z4S-LE SV-H series)
*
*For optical diagrams, refer to FH manual or catalog.
Connecting
Using the Camera cable FZ-VS□□(sold separately), connect the connector
on the back of the camera and the camera connector on Controller FH series.
Camera cable
FZ-VS□□
Enhancing connetor
Camera cable
connector
Name plate
* The camera cable FZ-VS□□ has polarity. Be sure to connect the side
with the name plate on it to the controller.
■Dimensions
(Unit : mm)
14.5
22
),
2
3-M2 DEPTH 3.0
40
7.3
14.5
22
28
11
OPTICAL AXIS
3-M2 DEPTH 3.0(BOTH SIDE)
24
5.5
33.5
9.5 9.5
10.5
1"-32UN-2A (C MOUNT)
19 ±0.1
2-M4 DEPTH 5.5
MOUNTING SCREW HOLES
1/4-20UNC DEPTH 5.5
* The base at the bottom of the camera can be mounted to the bottom, top,
and both sides. Remove the base mounting screw (M2x7) and correct the
mounting position. (Recommended mounting screw torque: 0.32 N ・ m)
Suitability for Use
Suitability for Use
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
s
D
O ct, 2014
5.4

Advertisement

loading

This manual is also suitable for:

Fm-sc05r