Image sensor for fh - 2 megapixel/4 megapixel digital camera

Advertisement

FH-S□02/S□04
Model
Image Sensor for FH - 2 Megapixel/4 Megapixel
Digital Camera
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
TRACEABILITY INFORMATION:
Representative in EU:
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
Ayabe Factory
3-2 Narutani, Nakayama-cho,
Ayabe-shi, Kyoto 623-0105 JAPAN
NOTICE:
This product meets CISPR11 class A. The intended use of this product is in an
industrial environment only.
© OMRON Corporation
2013
All Rights Reserved.
PRECAUTIONS ON SAFETY
Meaning of Alert Symbols
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury,
WARNING
or may result in serious injury or death. Additionally
there may be significant property damage.
Alert statements
WARNING
This product is not designed or rated for ensuring safety
of persons. Do not use it for such purposes.

PRECAUTIONS FOR SAFE USE

Be sure to respect following items for safety.
・ Tighten all screws securely during installation.
・ Do not connect the Sensor to the products other than the dedicated camera cable
(FZ-VS□□), controller (FH), electronic flash controller (FL-TCC1 and FLV-TCC
□), extension unit (FZ-VSJ). If the Sensor is connected to non-dedicated products
and turned the power on, the devices may be damaged and be heated to a high
temperature.
・ If you suspect an error or malfunction, stop using the Controller immediately, turn
OFF the power supply, and consult your OMRON representative.
・ Do not try to disassemble, repair, or modify the product.
・ Dispose of FZ-SC components as industrial waste.

PRECAUTIONS FOR CORRECT USE

Please observe the following precautions to prevent failure to operate, malfunction, or
undesirable effect.
1. Installation and storage of the product
Do not install in the following locations.
・ Locations where the ambient temperature exceeds the rated temperature range.
・ Locations subject to sudden temperature changes (where condensation will form).
・ Locations where there are corrosive or flammable gases.
・ Locations where there is dust, salt, or iron powder.
・ Locations where the device will be subject to direct vibration or shock.
・ Locations where there is strong scattered light.
・ Locations exposed to direct sunlight
・ Locations where there is splashing of water, oil, or chemicals.
・ Locations where there is a strong electrical or magnetic field.
・ Locations close to high-voltage devices and/or power devices
2. Cables
・ When connecting or disconnecting the camera cable or flash controller cable, be sure
to turn off the controller unit.
・ Do not use the camera cable exceeding the specified length.
・ When connecting the Sensor and the Controller (FH) with single camera cable,
connect the cable to CH1 of the camera connector.
・ When connecting the Sensor and the Controller (FH) with two camera cables, the type
and length of the camera cable must be matched.
・ When connecting the Sensor and the Controller (FH) with two camera cables, check
the CH numbers of the Controller side and Camera side before connecting.
・ Up to three camera cables can be connected using the extension unit FZ-VSJ. Be
sure to use the recommended camera cable with FZ-VSJ.
・ When connecting the camera cable, tighten the cable with the fixing screw with the
recommended torque (0.15 N ・ m). Applying excessive force to the camera connector
may cause failure of the product.
・ Use the ferrite core equivalent to ZCAT2035-0930A (manufactured by TDK) at the
controller side of the camera cable.
・ The camera cable FZ-VS□□ has polarity. Be sure to connect the side with the name
plate on it to the controller. Be sure to connect the side with the name plate on it to
the controller.
3. Mounting
The camera case is connected to the 0 V line of the internal circuit. Observe the
following precautions to prevent noise from entering the camera.
・ Do not ground the camera unit.
・ Be sure to use a base for installation. When mounting a base, engage it with the
specified screw (M4x8) with the recommended torque (1.2 N ・ m).
・ When securing the camera using the mounting hole on the lens face (front), be sure to
perform insulation.
4. Beam
・ The beam center may vary for each camera. Be sure to confirm the center position of
the image using the monitor before mounting. In the nature of the materials used, the
beam center of this product may change for the number of pixels due to changes in
ambient temperature.
5. Maintenance
・ Avoid using thinner, alcohol, benzene, acetone or kerosene to clean the product.
・ If there is large dirt or dust attached to the imaging element, blow them off with
blower brush (for camera lens). Do not use your breath to blow the dust off.
・ When the lens is not mounted, be sure to attach the C-mount cap on the lens mount. If
dirt or dust is attached to the image elements, false detection or failure may occur.
・ Be sure to attach a connector cap on unused connectors at the back of the camera.
Removing the connector cap may cause a foreign material entering in the camera,
causing false operation or failure.
・ Do not connect devices to the extension connector other than the dedicated ones
(FL-TCC1 or FLV-TCC□).
6. Imaging element
・ In the nature of imaging element, lines may appear in images due to measurement
conditions or sensitivities. This does not indicated a malfunction. Although there may
be multiple faulty pixels, this does not indicate a malfunction. If these conditions
affect measurement or inspection, use the CCD camera.
Ratings / Performance
General specifications
Model
FH-S□02
FH-S□04
Item
2.6 W max. (13 VDC)
Power consumption
Vibration
10 to 150Hz: half-amplitude: 0.35mm:(maximum acceleration: 50m/s
resistance
10 times for 8 minutes each in 3 directions
Shock resistance 150m/s
; 3 times each in 6 directions
Shock resistance
2
Operating: 0 to 40 ℃(with no icing nor condensation)
Ambient
Storage: -25 to 65 ℃ (with no icing nor condensation)
Temperature
Operating and storage: 35% to 85%
Ambient
(with no condensation)
humidity
Ambient
No corrosive gases
environment
Degree of
IEC60529 IP40 (in-panel)
protection
Center positional
X, Y : ±0.31mm
accuracy of
∂x, ∂y : ±1.7°
optical axis
Case: Aluminum
Materials
Camera base: PC/GF
Mount screw: brass
Weight
Approx. 110 g (including base)
Accessories
Instruction Sheet (this sheet)
Cable length
High speed mode: 5 m max.
Standard mode: Using FZ-VS2: 15 m max.
Using a dedicated product other
than FZ-VS2: 10 m max.
●Performance specifications
Model
FH-SC02
FH-SM02
FH-SC04
Item
2/3-inch
2/3-inch
1-inch
Picture element
color CMOS
monochrome
color CMOS
CMOS
2040(H)×1088(V)
Effective pixels
Pixel size
5.5 ( μm)×5.5(μm)
Scanning method
Progressive
High speed
2CH: 219 fps
mode*1
1CH: 109 fps
Frame
rate
Standard
2CH: 103 fps
mode*1
1CH: 51 fps
Synchronization
Internal
method
Digital (8 bits)
Video output
Gain
1 to 5 times
Exposure time
25μs∼100,000μs
Lens mounting*2
C mount(Recommended FH-S□02: 3Z4S-LE SV-H series
FH-S□04: 3Z4S-LE VS-H1 series)
*1 This Sensor has high speed mode and standard mode according to your
application.
High speed mode can be set in the system settings.
*2 For optical diagrams, refer to FH manual or catalog.
Connecting
Using the Camera cable FZ-VS□□(sold separately), connect the connector
on the back of the camera and the camera connector on Controller FH series.
Camera cable
FZ-VS□□
Camera cable
connector CH1
Name plate
* The camera cable FZ-VS□□ has polarity. Be sure to connect the side
with the name plate on it to the controller.
When connecting the product to the Controller with a single camera cable,
connect the cable to CH1 of the camera cable connector.
When connecting the product to the Controller with two camera cables,
connect it as shown below.
(connecting four Cameras)
Camera
Controller
),
2
FH-S□□□
FH
CH1
Camera connector 0
CH2
Camera connector 1
CH1
Camera connector 2
CH2
Camera connector 3
Camera connector 4
CH1
CH2
Camera connector 5
Camera connector 6
CH1
CH2
Camera connector 7
■Dimensions
(Unit : mm)
FH-SM04
1-inch
monochrome
CMOS
2040(H)×2048(V)
2CH: 118 fps
40
1CH: 59 fps
30
2CH: 55 fps
4-M4 DEPTH4
1CH: 27 fps
1"-32UNF(C MOUNT)
34
OPTICAL AXIS
19±0.1
MOUNTING SCREW HOLES
2-M4 DEPTH5.5
* The base at the bottom of the camera can be mounted to the bottom, top,
Camera cable
and both sides. Remove the base mounting screw (M4x8) and correct the
connector CH2
mounting position. (Recommended mounting screw torque: 1.2 N ・ m)
CH1
CH2
Suitability for Use
Enhancing connetor
Omron Companies shall not be responsible for conformity with any
standards, codes or regulations which apply to the combination of the
Product in the Buyer's application or use of the Product. At Buyer's request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the
Product in combination with the end product, machine, system, or other
application or use. Buyer shall be solely responsible for determining
appropriateness of the particular Product with respect to Buyer's application,
product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
CHINA
OMRON(CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222 Fax :86-21-5037-2200
OMRON Corporation
p
D
Apr, 201 3
14.5
22.7
4-M4 DEPTH4
40.5
8.2
14.5
22.7
9.5
22.2
4-M4 DEPTH4
15.5
19
9.5
1/4-20UNC DEPTH5.5