Terminal block X4
(for optoelectronic safety edge protection)
10
-
9
8
0V
-
Sig
7
+ 12 V
6
5
-
4
3
-
2
-
+
1
X4
Terminal block X3
(assignment)
- CLOSE switch
- impulse switch
X3
- OPEN switch
- STOP switch
- Emergency off, slack
rope switch, wicket
door contact, draw-in
protection
Impulse button
(sequence control)
- impulse button
CS covered input unit
- CLOSE switch
- OPEN switch
X13
- STOP switch
KDT covered input unit
- CLOSE switch
X7
- OPEN switch
- STOP switch
Terminal block X4
(for 8.2 kOhm safety edge protection)
PART – OPEN
2
safety edge protection
OPTO
photoelectric
8, 2 KOhm
drive-through barrier
3
24 V DC / 250 mA
4
OPEN / STOP / CLOSE buttons
(6-lead solution)
1
Key switch OPEN / CLOSE
Internal ON/OFF switch
X6
External radio
X12
Terminal block X4
(for pneumatic safety edge protection – pressure
sensor test)
10
- PART - OPEN
2
9
8
7
6
- safety edge protection
5
4
- photoelectric
3
drive-through barrier
3
2
1
- 24 V DC / 250 mA
4
OPEN / STOP / CLOSE buttons
(4-lead solution)
- CLOSE button
- OPEN button
- STOP button
- CLOSE
- OPEN
- impulse button
- OPEN switch
- GND
- 24 V DC
CS 300 Gate Controls / Rev.D 5.6 – 33
Pro-Line
SYSTEM
5
- PART - OPEN
2
- safety edge protection
8, 2 KOhm
- photoelectric
drive-through barrier
3
-
+
- 24 V DC / 250 mA
4
- CLOSE button
- OPEN button
- STOP button
1
sequence control
2
button or selector switch
3
effective in down direction
4
for external switching devices
(connection to terminals 1 and 2)
- A 8.2 kOhm resistor must be
5
connected in series
- The input parameter SEP TEST must
be switched on
ws:
white
gr:
green
br:
brown