Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• H_C1000(A/W)HS 208-230/60/1-15 amps
• H_E1000(A/W)HS 230/50/1-15 amps
(H_E1000A/W requires 15A circuit, 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water fi ltration system (#00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
• The drain line from the ice machine must have at least 1/4" per foot pitch (6,4mm/0,3m)
HARMONY • TOP-MOUNT
Stock Module Identification Plate
208264
Module No.
Product
Service No.
1/4" (6,4mm)
1' (0,3m)
2
wire)
self-contained

Site preparation

H_C1000A/W
NEMA
6-15
H_E1000A/W
requires 15A circuit,
1.50 mm
H_E1400A/W
requires 20A circuit,
4.00 mm
• H_C1400(A/W)HS 208-230/60/1-20 amps
• H_E1400(A/W)HS 230/50/1-20 amps
(H_E1400A/W requires 20A circuit, 4.00 mm
H_C1400A/W
NEMA
6-20
2
wire
2
wire
2
wire)
2
5