Site Preparation - Follett Horizon HME14000ABT Installation Instructions Manual

Table of Contents

Advertisement

Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of
icemaker in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• HCC1000(A/W)HS 208-230/60/1-15 amps
• HCE1000(A/W)HS 230/50/1-15 amps
(HCE1000A/W Requires 15 amp circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 F to 90 F (7 C to 32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 F to 90 F (7 C to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
• The drain line from the icemaker must have at least 1/4" per foot pitch (6,4mm/0,3m)
BIN • TOP-MOUNT
Stock Module Identification Plate
208264
Module No.
Product
Service No.
2
wire)
self-contained

Site preparation

HCE1000A/W
requires 15 amp circuit
1.50 mm
HCE1400A/W
requires 20 amp circuit
4.00 mm
1/4˝
1'
• HCC1400(A/W)HS 208-230/60/1-20 amps
• HCE1400(A/W)HS 230/50/1-20 amps
(HCE1400A/W Requires 20 amp circuit 4.00 mm
2
2
wire
2
wire
NEMA
6-15
HCC1000A/W
NEMA
6-20
HCC1400A/W
2
wire)
5