Download Print this page

Advanced Energy Thyro-PX Anybus Modbus TCP Manual page 30

Advertisement

®
Advanced Energy
Table 11. Parameter list (Continued)
API
Read /
Address
#
Write
Dec
187
Write
4484
188
Read
4486
189
4488
190
4490
191
4492
192
4494
193
Write
4496
194
Read
4498
195
4500
196
Read
4502
197
Read
4504
198
Read
4506
199
4508
200
Write
4510
201
Write
4512
202
Write
4514
203
4516
204
4518
205
Read
4520
206
4522
57010166-00A
Parameter Name
Hex
1184
I/O Ext1 Digital Out w
1186
I/O Ext1 Digital Out r
1188
118A
118C
118E
1190
I/O Ext2 Relay w
1192
I/O Ext2 Relay r
1194
1196
I/O Ext2 Analog In 1 r
1198
I/O Ext2 Analog In 2 r
119A
I/O Ext2 Analog In 3 r
119C
119E
I/O Ext2 Analog Out 1
w
11A0
I/O Ext2 Analog Out 2
w
11A2
I/O Ext2 Analog Out 3
w
11A4
11A6
11A8
I/O Ext2 Digital In r
11AA
Thyro-PX
Type
UINT16
I/O Extension 1: Digital output - write
Bit 0: Digital output 1
Bit 1: Digital output 2
UINT16
I/O Extension 1: Digital output - read
Bit 0: Digital output 1
Bit 1: Digital output 2
UINT16
I/O Extension 2: Relay - write
Bit 0: Relay 1
Bit 1: Relay 2
UINT16
I/O Extension 2: Relay - read
Bit 0: Relay 1
Bit 1: Relay 2
FLOAT
I/O Extension 2: Analog input 1 - read
FLOAT
I/O Extension 2: Analog input 2 - read
FLOAT
I/O Extension 2: Analog input 3 - read
FLOAT
I/O Extension 2: Analog output 1 - write
FLOAT
I/O Extension 2: Analog output 2 - write
FLOAT
I/O Extension 2: Analog output 3 - write
UINT16
I/O Extension 2: Digital input - read
Bit 0: Digital input 1
Bit 1: Digital input 2
®
Anybus
Modbus TCP
®
Thyro-PX
Anybus
Modbus TCP
Parameter Description
30

Hide quick links:

Advertisement

loading