® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP HARDWARE DESCRIPTION ® This module is compliant with the Ethernet IP standard, and supports 10/100Mbit, full or half duplex operation. Network status Link/activity port 1 Link/activity port 2 Module status RJ-45 connectors Figure 1. Hardware...
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Table 3. Link/activity LED (Continued) LED State Description Green 100 Mbit/s link established Green, flickering 100 Mbit/s activity Yellow 10 Mbit/s link established Yellow, flickering 10 Mbit/s activity Table 4. RJ-45 Ethernet pinout ...
Page 4
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP • Configure the flexible link parameters Adapting Thyro-PX Hardware Configuration Open parameter file with the unit online in the Port Explorer tab of the Thyro-Tool Pro PC software, or use the Thyro‑Touch display.
Page 5
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Figure 4. Ethernet IP module MAC address Selecting Configuration Figure 5. Select configuration Each configuration name, status, and selection is described in the following table: Table 5. Configuration Name Status/Selection Description...
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Table 5. Configuration (Continued) Name Status/Selection Description thereby avoiding unwanted effects due to an incomplete change. Motorpotentiometer = Motorpotentiometer = When enabled, the value of the motorpotentiometer Master Master continuously follows the master setpoint while in remote operation, so that no setpoint leap occurs during the switch-over to the local setpoint.
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Table 6. Default flexible links (Continued) Flexible Link Type Default Link Setting Flexible read-link 04 r FLOAT Power Controller #1: L1 Power - read Flexible read-link 05 r FLOAT Power Controller #1: L1 Resistance - read...
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP When an Anybus module is inserted into the unit, guide the module towards the left during insertion. 4. Secure each module with the two TORX ® T8 screws provided with the module.
Page 9
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP • Write assembly 103, with read assemblies: ◦ 112 ◦ 113 Write Assemblies Table 7. Write Assemblies Address Write Parameter by Thyro-PX Configuration Assembly 101 Assembly 102 Assembly 103...
Page 10
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Read Assemblies Table 8. Read Assemblies Address Read Parameter by Thyro-PX Configuration Assembly 111 Assembly 112 Assembly 113 Configuration Device Error device r Device Error device r Device Error device r...
Page 11
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP Table 8. Read Assemblies (Continued) Address Read Parameter by Thyro-PX Configuration Assembly 111 Assembly 112 Assembly 113 Configuration 00F2 Config read-link 02 r 00F3 Config read-link 03 r 00F4 Config read-link 04 r...
® ™ ® Advanced Energy Thyro-PX Anybus Ethernet IP AE GLOBAL SERVICES Please contact AE Global Services if you have questions or problems that cannot be resolved by working through the provided troubleshooting. When you call Global Services, make sure to have the unit serial number and part number.
Page 13
http://www.advanced-energy.com TRADEMARKS All Advanced Energy trademarks are the property of Advanced Energy Industries, Inc. For the list of Advanced Energy trademarks, visit http://www.advanced-energy.com/en/Trademarks.html. Any unauthorized use of Advanced Energy trademarks is prohibited. All other trademarks are the property of their respective owners.