Download Print this page

Advanced Energy Thyro-PX Anybus Modbus TCP Manual page 10

Advertisement

®
Advanced Energy
• Three-phase (1 * 3 phase)
Use the column in the following table which corresponds with your hardware configuration. For the
default flexible links, see
Table 9. Buffered read addresses
Address
Dec
Hex
1 * 1 phase
2048
800
Device Error
device r
2050
802
Device Error
extension r
2052
804
#1 Actual setpoint
r
2054
806
#1 Output r
2056
808
#1 Error PC r
2058
80A #1 Status PC r
2060
80C
#1 Monitoring PC
r
2062
80E
Flexible link 01 r
[1]
2064
810
Flexible link 02 r
2066
812
Flexible link 03 r
2068
814
Flexible link 04 r
2070
816
Flexible link 05 r
2072
818
Flexible link 06 r
2074
81A Flexible link 07 r
2076
81C
Flexible link 08 r
2078
81E
Flexible link 09 r
2080
820
Flexible link 10 r
2082
822
Flexible link 11 r
2084
824
Flexible link 12 r
2086
826
Flexible link 13 r
2088
828
Flexible link 14 r
2090
82A Flexible link 15 r
2092
82C
Flexible link 16 r
2094
82E
Flexible link 17 r
57010166-00A
"Default Flexible Links"
Read Parameter by Thyro-PX Configuration
2 * 1 phase
3 * 1 phase
Device Error
Device Error
device r
device r
Device Error
Device Error
extension r
extension r
#1 Actual setpoint
#1 Actual
r
setpoint r
#1 Output r
#1 Output r
#1 Error PC r
#1 Error PC r
#1 Status PC r
#1 Status PC r
#1 Monitoring PC
#1 Monitoring PC
r
r
#2 Actual setpoint
#2 Actual
r
setpoint r
#2 Output r
#2 Output r
#2 Error PC r
#2 Error PC r
#2 Status PC r
#2 Status PC r
#2 Monitoring PC
#2 Monitoring PC
r
r
Flexible link 01 r
#3 Actual
setpoint r
Flexible link 02 r
#3 Output r
Flexible link 03 r
#3 Error PC r
Flexible link 04 r
#3 Status PC r
Flexible link 05 r
#3 Monitoring PC
r
Flexible link 06 r
Flexible link 01 r Flexible link 11 r
Flexible link 07 r
Flexible link 02 r Flexible link 12 r
Flexible link 08 r
Flexible link 03 r Flexible link 13 r
Flexible link 09 r
Flexible link 04 r Flexible link 14 r
Flexible link 10 r
Flexible link 05 r Flexible link 15 r
Flexible link 11 r
Flexible link 06 r Flexible link 16 r
Flexible link 12 r
Flexible link 07 r Flexible link 17 r
Thyro-PX
Anybus
Thyro-PX
on page 7.
1 * 2 phase
Device Error
device r
Device Error
extension r
#1 Actual setpoint
r
#1 Output r
#1 Error PC r
#1 Status PC r
#1 Monitoring PC
r
Flexible link 01 r
Flexible link 02 r
Flexible link 03 r
Flexible link 04 r
Flexible link 05 r
Flexible link 06 r
Flexible link 07 r
Flexible link 08 r
Flexible link 09 r
Flexible link 10 r
®
Modbus TCP
®
Anybus
Modbus TCP
1 * 3 phase
Device Error
device r
Device Error
extension r
#1 Actual setpoint
r
#1 Output r
#1 Error PC r
#1 Status PC r
#1 Monitoring PC
r
Flexible link 01 r
Flexible link 02 r
Flexible link 03 r
Flexible link 04 r
Flexible link 05 r
Flexible link 06 r
Flexible link 07 r
Flexible link 08 r
Flexible link 09 r
Flexible link 10 r
Flexible link 11 r
Flexible link 12 r
Flexible link 13 r
Flexible link 14 r
Flexible link 15 r
Flexible link 16 r
Flexible link 17 r
10