Download Print this page

Advertisement

Thyro-PX
Guide
ANYBUS MODBUS TCP MODULE
The Anybus Modbus TCP module is an optional accessory for the Thyro-PX power controller.
Related Links
This document and the information contained herein are the proprietary property of Advanced
Energy Industries, Inc. Copyright© 2017 Advanced Energy Industries, Inc. All Rights Reserved.
Anybus
®
Modbus TCP
57010166-00A January 2017
Related Documentation
For complete information on the Thyro-PX unit,
see the user manual that accompanied the
system. In particular, reference the safety
information in Chapter 1 of the user manual for
the Thyro-PX unit.

Advertisement

loading

Summary of Contents for Advanced Energy Thyro-PX Anybus Modbus TCP

  • Page 1: Table Of Contents

    • “Modbus TCP Parameter List” on page 13 • “AE Global Services” on page 34 This document and the information contained herein are the proprietary property of Advanced Energy Industries, Inc. Copyright© 2017 Advanced Energy Industries, Inc. All Rights Reserved.
  • Page 2: Hardware Description

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP   HARDWARE DESCRIPTION ® This module is compliant with the Modbus TCP standard. Network status Link/activity port 1 Link/activity port 2 Module status RJ-45 connectors Figure 1. Hardware   Table 1. Network status LED  ...
  • Page 3: Configuring With Thyro-Tool Pro Pc Software

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 3. Link/activity LED (Continued)   LED State Description Green, flickering 100 Mbit/s activity Yellow 10 Mbit/s link established Yellow, flickering 10 Mbit/s activity   Table 4. RJ-45 Ethernet pinout   Description 4, 5, 7, 8 Normally left unused;...
  • Page 4 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Figure 2. Menu tree Anybus Parameter Group When the computer is connected to the Thyro-PX power controller, the Anybus parameter group will be added to the parameter list after updating the hardware configuration, as shown in the previous figure.
  • Page 5 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Figure 4. Configure Modbus TCP IP address Connecting to the Modbus TCP controller Some process control software can scan the network to automatically detect and connect to Modbus TCP devices. To manually configure the process control software, find the MAC address for the Modbus TCP module in the General menu.
  • Page 6 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Selecting Configuration Figure 6. Select configuration Each configuration name, status, and selection is described in the following table:   Table 5. Configuration   Name Status/Selection Description Control of validity Cyclic telegram valid...
  • Page 7: Default Flexible Links

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Configuring Diagnostics Modbus TCP diagnostic information is available according to the following tables.   Table 6.   Input Register Diagnostic event count 2048 Number of pending diagnostic events. There may be gaps between active diagnostic events.
  • Page 8: Installing Optional Modules

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 8. Default flexible links   Flexible Link Default Link Setting Flexible read-link 01 r Power Controller #1: Total power - read Flexible read-link 02 r Power Controller #1: L1 Urms - read...
  • Page 9: Fast Process Data Communication

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP 2. Unpack each optional module at an ESD safe work space. 3. Plug each optional module into the unit. When an Anybus module is inserted into the unit, guide the module towards the left during insertion.
  • Page 10 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP • Three-phase (1 * 3 phase) Use the column in the following table which corresponds with your hardware configuration. For the default flexible links, see “Default Flexible Links” on page 7.
  • Page 11 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 9. Buffered read addresses (Continued)   Address Read Parameter by Thyro-PX Configuration 1 * 1 phase 2 * 1 phase 3 * 1 phase 1 * 2 phase 1 * 3 phase...
  • Page 12 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 10. Buffered write addresses (Continued)   Address Write Parameter by Thyro-PX Configuration 1 * 1 phase 2 * 1 phase 3 * 1 phase 1 * 2 phase 1 * 3 phase...
  • Page 13: Modbus Tcp Parameter List

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP   MODBUS TCP PARAMETER LIST   Table 11. Parameter list   Read / Address Parameter Name Type Parameter Description Write Read 4112 1010 Flexible link 01 r UINT32 Flexible link number 01 - read...
  • Page 14 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4144 1030 Flexible link 17 r UINT32 Flexible link number 17 - read FLOAT Read 4146...
  • Page 15 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Write 4182 1056 Flexible link 16 w UINT32 Flexible link number 16 - write FLOAT Write 4184...
  • Page 16 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4198 1066 Device CPU temperature FLOAT CPU temperature - read Read 4200 1068 Device error r...
  • Page 17 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4202 106A Device error extension r UINT32 Error extension - read Bit 1: Extension card X53 error...
  • Page 18 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4228 1084 #1 Error PC r UINT32 Error PC - read Bit 4: Synchronization error Bit 5: Phase missing...
  • Page 19 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4232 1088 #1 Monitoring PC r UINT32 Power controller #1: Monitoring PC - read Bit 4: U <...
  • Page 20 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4252 109C #1 L1 Resistance r FLOAT Power controller #1: L1 Resistance - read Read 4254...
  • Page 21 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4304 10D0 #1 L3 External control r FLOAT Power controller #1: L3 External control - read...
  • Page 22 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4332 10EC #2 Status PC r UINT32 Power controller #2: Status PC - read Bit 0: Output (pulses) on...
  • Page 23 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4334 10EE #2 Monitoring PC r UINT32 Power controller #2: Monitoring PC - read Bit 4: U <...
  • Page 24 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4354 1102 #2 L1 Resistance r FLOAT Power controller #2: L1 Resistance - read Read 4356...
  • Page 25 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4386 1122 #3 Status PC r UINT32 Power controller #3: Status PC - read Bit 0: Output (pulses) on...
  • Page 26 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4388 1124 #3 Monitoring PC r UINT32 Power controller #3: Monitoring PC - read Bit 4: U <...
  • Page 27 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4408 1138 #3 L1 Resistance r FLOAT Power controller #3: L1 Resistance - read Read 4410...
  • Page 28 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4418 1142 I/O Int LED 1-7 rd/gr r UINT16 Internal I/O: LED 1-7 - red/green - read...
  • Page 29 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Read 4446 115E I/O Int Digital In 1-6 r UINT16 Internal I/O: Digital input 1-6 - read...
  • Page 30 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Write 4484 1184 I/O Ext1 Digital Out w UINT16 I/O Extension 1: Digital output - write Bit 0: Digital output 1...
  • Page 31 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Write 4524 11AC I/O Ext2 Digital Out w UINT16 I/O Extension 2: Digital output - write Bit 0: Digital output 1...
  • Page 32 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Write 4554 11CA #2 Starting mode w UINT8 Power controller #2: Starting mode - write 0: None...
  • Page 33 ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP Table 11. Parameter list (Continued)   Read / Address Parameter Name Type Parameter Description Write Write 4576 11E0 #3 Control mode w UINT8 Power controller #3: Control mode - write 0: None...
  • Page 34: Ae Global Services

    ® ™ ® Advanced Energy Thyro-PX Anybus Modbus TCP AE GLOBAL SERVICES     Please contact AE Global Services if you have questions or problems that cannot be resolved by working through the provided troubleshooting. When you call Global Services, make sure to have the unit serial number and part number.
  • Page 35   http://www.advanced-energy.com TRADEMARKS All Advanced Energy trademarks are the property of Advanced Energy Industries, Inc. For the list of Advanced Energy trademarks, visit http://www.advanced-energy.com/en/Trademarks.html. Any unauthorized use of Advanced Energy trademarks is prohibited. All other trademarks are the property of their respective owners.