VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS

SPECIFICATIONS

Body Pattern: Straight through; See Table 1 for inlet and
outlet size.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 60 Hz or 50/60 Hz
depending on model.
Current Draw: 0.5A with both operators energized.
Capacity: See Table 1.
Conversion:
Use conversion factors in Table 2 to convert capacities for
other gases.
Regulation Range: See Table 1.
Natural-LP Gas Conversion Kits: See Table 4.
Pipe Adapters:
Angle and straight adapters available for 3/8-, 1/2- and
3/4-in. pipe. See Table 5. Flange kits include one
flange with attached O-ring, four mounting screws, a
9/64 in. hex wrench and instructions.
Approvals:
American Gas Association Design Certificate: L2025006.
Canadian Gas Association Design Certificate: L2025006.
Australian Gas Association Design Certificate: 4214.
Approved for Delta C applications.
European Community (CE) Certificate: Pending.
Model No. Suffix Letter
H, K, M
P
Q
R
Inlet/Outlet Pipe
Size (in. NPT)
3/8
Straight
3/8
Elbow
1/2
Straight
1/2
Elbow
3/4
Straight
3/4
Elbow
a
Flange kits include one flange, one O-ring and four mounting screws.
b
Do not use flanges on control models with 3/4 in. inlet and 3/4 in. outlet. On models with 1/2 in. inlet and 3/4 in. outlet,
use flanges only on the 1/2 in. inlet side.
Table 6 shows additional specifications for the CE-only
models.
69-1226—04
Table 4. Natural-LP Gas Conversion Kits.
Kit to Convert Natural Gas to LP
393691
Not field convertible.
396021
Not required, convertible valve.
Table 5. Flange Adapter Part Numbers.
Flange Type

PLANNING THE INSTALLATION

WARNING
Fire or Explosion Hazard.
Can cause severe injury, death or property
damage.
Follow these warnings exactly:
1. Plan the installation as outlined below.
2. Plan for frequent maintenance as described in
the Maintenance section.
Heavy demands are made on the controls when direct
ignition systems are used on central heating equipment in
barns, greenhouses, and commercial properties and on
heating appliances such as commercial cookers,
agricultural equipment, industrial heating equipment and
pool heaters.
Special steps may be required to prevent nuisance
shutdowns and control failures due to frequent cycling,
severe environmental conditions related to moisture,
corrosive chemicals, dust or excessive heat. These
applications require Honeywell Engineering review;
contact your Honeywell Sales Representative for
assistance.
Review the following conditions that can apply to your
specific installation and follow the precautions suggested.

Frequent Cycling

this control is designed for use on appliances that typically
cycle three to four times an hour only during the heating
season. In year-around applications with greater cycling
rates, the control can wear out more quickly. Perform a
monthly check.
Without Hex Wrench
393690-1
393690-2
393690-6
393690-3
393690-4
393690-5
2
Kit to Convert LP to Natural Gas
394588
Not field convertible.
396025
Not required, convertible valve.
a,b
Part Number
With Hex Wrench
393690-11
393690-12
393690-16
393690-13
393690-14
393690-15