VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
WHEN FLANGE IS NOT USED
APPLY WRENCH
FROM TOP OR
BOTTOM OF GAS
CONTROL TO
EITHER SHADED AREA
Fig. 5. Proper use of wrench on gas control with and without flanges.
HI-LO
ADJUSTMENT SCREWS
(UNDER CAP)
REGULATOR
VENT COVER
INLET
Wiring
WARNING
Electrical Shock Hazard.
Can cause severe injury, death or property
damage.
Disconnect the power supply before making wiring
connections. More than one disconnect may be
involved.
Follow the wiring instructions furnished by the appliance
manufacturer, if available, or use the general instructions
provided below. When these instructions differ from the
appliance manufacturer, follow the appliance
manufacturer instructions.
69-1226—04
LO
HI
TWO-STAGE
PRESSURE
REGULATOR
MODEL
Fig. 6. Top view of gas control.
PRESSURE REGULATOR
WIRING
ADJUSTMENT (UNDER
TERMINALS (2)
CAP SCREW)
INLET
PRESSURE TAP
INLET
All wiring must comply with applicable electrical codes
and ordinances.
1. Disconnect power supply before making wiring
connections to prevent electrical shock or
equipment damage.
2. Check the power supply rating on the gas control
and make sure it matches the available supply.
Install a transformer and other controls as required.
3. Connect the control circuit to the gas control
terminals. See Fig. 7 and 8.
4. Adjust thermostat heat anticipator to 0.50A rating
stamped on valve operator.
6
WHEN FLANGE IS USED
APPLY WRENCH
TO FLANGE ONLY
M3084A
OUTLET
PRESSURE
TAP
OUTLET
GAS CONTROL KNOB
M10967A