INSTRUCTIONS TO THE
HOMEOWNER
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death or property
damage.
Follow these warnings exactly:
1. Before lighting, smell around the appliance for
gas. Be sure to smell next to floor because LP
gas is heavier than air. If you smell gas:
(a) Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
the gas supply at the gas tank.
(b) Do not light any appliance in the house.
(c) Do not touch electrical switches or use the
telephone.
(d) Leave the building and use a neighbor's
phone to call your gas supplier.
(e) If you cannot reach your gas supplier, call
the fire department.
2. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
IMPORTANT:
Follow the operating instructions provided by the
heating appliance manufacturer. The information
below describes a typical control application, but
the specific controls used and the procedures
outlined in your appliance manufacturer
instructions can differ, requiring special
instructions.
VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS
To Turn ON Appliance
STOP: Read the Warnings Above Before
Proceeding
1. The lighting sequence on this appliance is
automatic; do not attempt to manually light the main
burner.
2. If the furnace does not come on when the
thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.
3. Remove the burner access panel, if provided, on
your appliance.
4. Turn the gas control knob clockwise
5. Wait five minutes to allow any gas in the
combustion chamber to vent. Then, if you smell
gas, STOP! Follow Step 1 in the Warning above. If
you do not smell gas, continue with the next step.
6. If you do not smell gas, turn the knob on the gas
control counterclockwise
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the appliance does not turn on, turn the gas
control knob to OFF and contact a qualified service
technician for assistance.

Turning Off the Appliance

Vacation Shutdown
Set the thermostat to the desired room temperature while
you are away.
Complete Shutdown
1. Turn off the power to the appliance.
2. Turn off the gas supply to the appliance.
3. Turn gas control knob clockwise
Appliance will completely shut off.
Follow the procedures in the Instructions to the
Homeowner section above to resume normal operation.
11
to OFF.
to ON.
to OFF.
69-1226—04