Specifications - Honeywell VC Series Installation Manual

Zone valves
Hide thumbs Also See for VC Series:
Table of Contents

Advertisement

VC SERIES

Specifications

Medium
pH-value
Operating temperature
Ambient temperature
Operating pressure
Differential pressure
k
(cv)-values
vs
Flow
Function
VC Series 2-position hydronic valves are used in domestic
and small commercial applications to control the flow of hot
and/or cold water. They consist of an actuator, valve and a
cartridge assembly.All moving and sealing parts of the valve
are constructed in the cartridge assembly. The ports are
sealed with O-rings on the outer surface of the piston.
When the valve stem is driven down to open port A the water
will flow through the hollow piston to the other port. In case of
2-way valve
With an SPDT (3-wire) actuator
On a call for heat, the NO controller contacts close and the
valve opens. When the valve is fully open, the cam closes
switch SW1 and opens switch SW2. When the need for heat
is satisfied the NC controller contacts close, energising the
valve through SW1 and closing the valve. When the valve is
fully closed, the cam closes SW2 and opens SW1. The valve
is ready for the next call for heat.
With an SPST (2-wire and common) actuator
On a call for heat, the controller contacts close, RLY1 is e-
nergized making the NO contacts in switch SW3 causing the
valve to open. When the valve reaches the fully open position
the cam closes switch SW1 and opens switch SW2. When
the need for heat is satisfied, the controller contacts open,
RLY1 is de-energized and the valve motor is driven through
SW1 and the NC contacts of SW3. When the valve reaches
the fully closed position, the cam closes SW2 and opens
SW1. The valve is ready for the next call for heat.
EN0H-0327GE25 R0206
Water or water-glycol mixture
(max. 50% glycol content),
quality to VDI 2035
8...9.5
1...95°C (34...203°F)
120°C (248°F) short duration
peak
max. 65°C (149°F)
max. 20 bar (290 psi) static
max. 100 bar (1,450 psi) burst
max. 4 bar (58 psi)
see chapter "Dimensions" below
2-way: flow can be in either
direction. When actuator is not
mounted valve is in closed
position
3-way: bottom port is marked
AB. End ports are marked A and
B. When actuator is not
mounted port A is closed.
Voltage
Power consumption
Auxiliary switch rating
Nominal timing
Electrical termination
Shipping temperature
Humidity rating
Atmosphere
a 3-way valve with the piston driven down port B is sealed,
allowing flow between port AB and port A. With the stem up
the flow is between port AB and port B.
The valve family offers a variety of versions of pipe connecti-
ons to suit the different applications. The valve pressure loss
characteristic is dependent on the pipe connections/ dimensi-
ons. For the actual valve rating please refer to the specificati-
on section.
For both types of actuator a power failure will leave the valve
at the position it was when interrupted. When power is resto-
red, the valve will respond to controller demand.
Fig. 1. Fluid flow through 2-way VC valve
2
24 V, 50-60 Hz (blue label)
200-240 V, 50-60 Hz (red label)
4 VA
(when valve position changes)
1.0 A @ 250 V, 50-60 Hz
(minimum 0.05 A @ 24 Vdc)
Valve opens in 7 seconds
(20% faster for 60 Hz)
1. Molex™ socket: requires
mating connector,
alternatively
2. With integral 1 m leadwire
-40...65°C (-40...149°F)
5...95% RH (non-condensing)
non-corrosive, non-explosive
Honeywell • All rights reserved