Technical Specifications - E.T. Systems Drive 500 User Instructions

500kg slide gate operators
Hide thumbs Also See for Drive 500:
Table of Contents

Advertisement

5.
It is highly recommended that a set of safety infra-red beams be used in conjunc on with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or gate.
6.
Over and above the recommenda on to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automa c closing feature. It is recommended that a warning light be fi ed to any automa on system.
7.
The emergency manual release instruc on label must be installed on or adjacent to the emergency manual release mechanism.
A er installa on - It is the responsibility of the installer to ensure the users:
1.
Is profi cient in the use of the manual emergency release mechanism.
2.
Is issued with the documenta on accompanying this product.
3.
Understands that the gate or door may not be operated out of clear sight.
4.
Ensures that children are kept clear of the gate or door area at all mes, and that children do not play with the remote transmi ers
or any fi xed trigger switches linked to the system.
5.
Is instructed not to a empt to repair or adjust the automa on system and to be aware of the danger of con nuing to use the
automa on system in an unsafe condi on before a service provider a ends to it.
6.
Is profi cient in tes ng the unit's safety obstruc on sensing system.
7.
Is aware of what to check for with regards to wear and tear that may need to be a ended to from me to me by the service
provider.
8.
Is aware that a fa gued ba ery may not be disposed of in the general refuse and must be handed in at a ba ery merchant for safe
disposal. Before removing the ba ery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the ba ery must be removed fi rst.
Technical Data
Rated gate mass.
Maximum gate travel.
Primary power supply to gate.
Peak power consump on at gate.
Electrical class.
Motor voltage.
Motor current.
Duty cycle maximum.
See determining your duty cycle on page 7.
Number of opera ons on ba ery reserve.
(Ba ery health and charge level at me of
power failure dependent. Calculated on a 5m
gate with rolling resistance of <10kgf)
Gate speed.
(Gate load and power supply dependent)
Rated Load.
Opera ng temperature range.
An -crushing safety sensing.
Auxiliary supply output.
Built in ba ery charger.
Receiver format.
Receiver frequency.
Receiver channels.
Receiver memory capacity.
All users can be allowed control of all channels.
Ingress protec on
Physical dimensions
Technical specifi ca ons.

TECHNICAL SPECIFICATIONS

Drive 500
500kg
99m
16Vac @ 1A 50Hz – 60Hz
26W
Class 3
12Vdc
Current limited to 25A.
25% with 220Vac present
100 using the standard 7Ah ba ery within
24hrs.
Up to 28m/min.
300N
-10 to 50° C (14F to 122F)
Yes – Electronic gate profi ling
12Vdc @ 500mA
Mul ple stage auto-calibra ng 1A
ET BLU MIX © backward compa ble with ET
BLUE (Rolling code)
433.92MHz
4CH (BT, PED, Aux relay, Holiday lock-out)
1023 users
Yes
IPX4
See next page.
4
Drive 600
500kg
99m
220 – 240Vac @ 50Hz – 60Hz
240W
Class 1
12Vdc
Current limited to 25A.
98% with 220Vac present
100 using the standard 7Ah ba ery within
24hrs.
Up to 30m/min.
300N
-10 to 50° C (14F to 122F)
Yes – Electronic gate profi ling
12Vdc @ 500mA
Mul ple stage auto-calibra ng 1A
ET BLU MIX © backward compa ble with ET
BLUE (Rolling code)
433.92MHz
4CH (BT, PED, Aux relay, Holiday lock-out)
1023 users
Yes
IPX4
See next page.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drive 600

Table of Contents