Tamper Alarms; Beam Tamper In Closed Position; Gate Kept Open Too Long Alarm - E.T. Systems Drive 500 User Instructions

500kg slide gate operators
Hide thumbs Also See for Drive 500:
Table of Contents

Advertisement

Advanced features
In cases where the safety beams have been tampered with, the safety protocols will s ll allow the gates to open but will not allow the gates to close.
This safety feature can be turned into a security risk by anyone with ill inten on. The safety beam input tampering alarm feature gives you a ealry
warning of any tampering that may have occured while you were away from the property. If the gates are in the closed posi on and the safety beam
input is trigger for longer than 20 seconds, then the alarm output will become ac ve. This output would usually be connected to a visual warning
device such as a light or to a zone on the household alarm system.
In the case of a light being used, on approach to the entrance the user is alerted to the a empt to compromise their security. Our advise is that the
user not trigger the gates to open, in this situa on, but rather to con nue driving to their nearest armed response standby point or to the nearest
police sta on. This way they can ask for an escort onto the property.
Safety beam alarm mode is available in all modes of opera on so long as a set of safety beams is installed.
Ac on
Safety beam equipment
tampered with while
gates are in the closed
posi on.
20 seconds a er safety
beam equipment has
been tampered with.
Safety beam equipment
returned to normal
func oning status.
Advanced features
In a cases where the user would like to be no fi ed of the gate being kept open for longer than a predetermined me period, the gate jammed open
alarm can be setup. The alarm condi on will reset to off when the gate is closed again.
Ac on
Gate prevented from
closing.
A er programmed gate
jammed open me.
Gate returns to full
closed posi on.
Gate closed.
Alarm output
remains in
standby status.
Alarm output
ac vates.
Alarm output
returns to
standby.
Alarm output
remains in
standby status.
Alarm output
ac vates.
Alarm output
returns to
standby.

Tamper alarms.

Beam tamper in closed posi on.
Built in buzzer sounding is
op onal.

Gate kept open too long alarm.

Built in buzzer sounding is
op onal.
22
Response
Response

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drive 600

Table of Contents