Analog video output signals

Signal Type
Preview Out
Composite Video
Y/C Video
Luminance signal
Chrominance signal
Program Out
Composite Video
Y/C Video
Luminance signal
Chrominance signal
Component Video
(Y, (B-Y), (R-Y))
Linear Key Out

Serial digital video input/output

Signal Type
Reference In
Reference Loop Out
Quantity
1
1
PAL: 700 mV at 100% Color Bar
NTSC: 700 mV at 75% Color Bar
1
1
PAL: 700 mV at 100% Color Bar
NTSC: 700 mV at 75% Color Bar
1
1
Quantity
1
1
Voltage
1.0 V
p-p
1.0 V
p-p
1.0 V
p-p
1.0 V
p-p
1.0 V
p-p
1.0 V
p-p
Voltage
2.0 V
p-p
1.0 V
p-p
DigiSuite LX electrical specifications
Impedance
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
75 Ω
no burst
Impedance
Hi Z
75
(terminated)
Hi Z (looped through)
121