SPECIFICATIONS
This chapter describes the performance specifications.
2.1
Performance Specifications
The following table lists the performance specifications of the temperature control module.
Item
Control output
Number of temperature input points
Applicable thermocouple/platinum resistance thermometer
*1
Accuracy
Indication accuracy
Cold junction
temperature
compensation
accuracy (Ambient
temperature: 0 to
55)
Sampling cycle
Control output cycle
Input impedance
Input filter
Sensor correction value setting
Operation at a sensor input disconnection
Temperature control method
PID constants
PID constants setting
range
Proportional band (P)
Integral time (I)
Derivative time (D)
Set value setting range
Dead band setting range
Transistor
Output signal
output
Rated load voltage
Maximum load current
Maximum inrush current
Leakage current at OFF
Maximum voltage drop at ON
Response time
Number of accesses to non-volatile memory
Insulation method
2 SPECIFICATIONS
18
2.1 Performance Specifications
R60TCTRT2TT2
Transistor output
4 channels/module
Refer to the following.
Page 20 Type of Temperature Sensors, Temperature Measuring Range, Resolution,
and Effect from Wiring Resistance
Full scale (0.3%)
Ambient temperature:
255
Full scale (0.7%)
Ambient temperature: 0 to
55
Within 1.0
Temperature process
value: -100 or higher
Within 2.0
Temperature process
value: -150 to -100
Within 3.0
Temperature process
value: -200 to -150
Switchable between 250ms/4 channels and 500ms/4 channels
0.5 to 100.0s
1M
0 to 100s (0: Input filter OFF)
■When the R mode is used
(-(full scale of input range)) to full scale of input range
■When the Q compatible mode function is used
-50.00 to 50.00%
Upscale processing
PID ON/OFF pulse or two-position control
Setting by auto tuning is available.
■When the R mode is used
0 (0.0) to full scale of input range (depending on the decimal point position) (0: Two-
position control)
■When the Q compatible mode function is used
0.0 to 1000.0% (0: Two-position control)
0 to 3600s (Set 0 for P control and PD control.)
0 to 3600s (Set 0 for P control and PI control.)
Within the temperature range set in the thermocouple/platinum resistance thermometer to
be used
■When the R mode is used
0 (0.0) to full scale of input range (depending on the decimal point position)
■When the Q compatible mode function is used
0.1 to 10.0%
ON/OFF pulse
10 to 30VDC
0.1A/point, 0.4A/common
0.4A, 10ms
0.1mA or lower
1.0VDC (TYP) 0.1A, 2.5VDC (MAX) 0.1A
OFFON: 2ms or less, ONOFF: 2ms or less
12
10
Between the input terminal and PLC power supply: Transformer
Between input channels: Transformer
R60TCRT4
times maximum
R60TCTRT2TT2BW
R60TCRT4BW
Within 1.0
Within 2.0
Within 3.0