Keypad set up of the parameters for Signal Cumulate Timing:
To enter the page for parameter setting of the timer, press
setup is complete, press
Ä
main menu.
Select funtions: There are 4 modes in CTT, (left to right) timer, counter, tachometer and timer + counter.
–funC
time
or
Ä
Select timer mode: timing up and timing down
t–mode
–up
or
Ä
Select output modes: There are 12 output modes in the timer. The user can choose the mode that best
meets the demand.
t–otmd
sond1
or
Ä
–rCy
or
Select display unit: the min. unit 10ms to the max. unit hour are selectable. Refer to table below.
t–unit
s–001
or
Ä
–m–1
or
Select pulse width of output 1: The default output time is 0.02 second. When the parameter is set to 0.00
second, the output status will continue.
t–out1
–002
or
Ä
Select min. width of reset signal: The defaul value is 20ms; can be set to 1ms.
–rtsr
––20
or
Ä
Select input signal types: NPN and PNP (use NPN if dry contact input)
inptlC
–npn
or
Ä
Back to Top
t–unit
sec.
s–001
sec.
s–01
sec.
–s–1
min., sec.
ms–001
min., sec.
ms–01
min.
m–01
min.
–m–1
hr., min., sec.
hms–1
hr., min.
hm–1
hr.
–h–1
w w w . a u t o m a t i o n d i r e c t . c o m
for more than 3 seconds under any of the paramter page you are in and return to the
Cont
or
or
down
or
sond2
or
or
rCyh
or
or
s–01
or
or
hms–1
or
or
–000
or
–––1
or
–pnp
or
Setting Time Units
0.01 to 9,999.99
0.1 to 99,999.9
1 to 999,999
0.01 to 9,959.99
0.1 to 99,959.9
0.1 to 99,999.9
1 to 999,999
1 to 995,959
1 to 999,959
1 to 699,999
Digital Counter / Timer / Tach User Manual, 1st Ed.
in the main menu for more than 3 seconds. After the
Ä
taCH
–mix
or
soffd
–son
or
rCy2
sCon
or
–s–1
ms–001
or
hm–1
–h–1
or
A unit = 10ms
A unit = 0.1 sec.
A unit = 1 sec.
A unit = 0.01 sec.
A unit = 0.1 sec.
A unit = 0.1 min.
A unit = 1 min.
A unit = 1 sec.
A unit = 1 min.
A unit = 1 hr.
pond
pondh
or
or
ston
stoff
or
or
ms–01
m–01
or
or
Max. counting = 9,999.99 secs.
Max. counting = 99,999.9 secs.
Max. counting = 999,999 secs.
Max. counting = 5,999.99 secs.
Max. counting = 59,999.9 secs.
Max. counting = 99,999.9 mins.
Max. counting = 999,999 mins.
Max. counting = 359,999 secs. (100 hrs.)
Max. counting = 35,999,999 secs. (10,000 hrs.)
Max. counting = 699,999 hrs.
3-23

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTT-1C-D24 and is the answer not in the manual?

Questions and answers

Ron Hurst
April 28, 2025

How to set oven or time on CTT-1-C-D24

This manual is also suitable for:

Ctt-an-d24Ctt-1c-a120Ctt-an-a120

Table of Contents

Save PDF