CTT Counter Functions
Total Counting ( total )
Counting Up (UP)
Total Counting ( totAL )
A single count setting value SV is available in Total Counting. Both Outputs 1 and 2 operate concurrently and will
turn ON momentarily for the time set in the output pulse width parameter ( tout2 ) or will be maintained ON
depending on the Output Mode selected.
Input Mode:
Counting Up ( UP )
With the input signal OFF at input CP2, each leading edge of the
input signal at CP1 will increment the count present value PV by
1. Turning ON the input signal at CP2, will prohibit the input
signal at CP1 from incrementing the PV.
With the input signal ON at input CP1, each trailing edge of the
input signal at CP2 will increment the count present value PV by
1. Turning OFF the input signal at CP1, will prohibit the input
signal at CP2 from incrementing the PV.
Output Modes:
Mode F ( F )
The Total PV increments with each count present value PV.
When the count present value PV counts up to the count
setting value SV both outputs 1 and 2 will turn ON. The count
PV and Total PV will continue to increment with each input
signal.
The leading edge of a "reset" input signal at RST1 will turn
OFF both outputs, reset the count present value PV to 0, and
prohibit an input signal from incrementing the count PV. The
trailing edge of the "reset" signal at RST1 enables counting to
begin.
The leading edge of a "reset" input signal at RST2 will reset the
Total PV to 0, and prohibit an input signal from incrementing
the Total PV. The trailing edge of the "reset" signal at RST2
enables counting to begin.
The "reset" signal minimum pulse width is set by reset pulse
width parameter ( rtSr ) or DIP Switch 8.
w w w . a u t o m a t i o n d i r e c t . c o m
Digital Counter / Timer / Tach User Manual, 1st Ed.
Counting up
CP1: Counter input
CP2: Counter input prohibited
H
CP1
L
A
Prohibit
H
CP2
L
Present
2
Value
1
0
0
Note:
has to be larger than width of min. Input signal
A
CP1: Counter input prohibited
CP2: Counter input
H
CP1
L
A
Prohibit
H
CP2
L
Present
Value
2
1
0
0
Note:
A
has to be larger than width of min. Input signal
RST1
RESET
999999
COUNT SV
COUNT PV
0
OUT1
OUT2
RST2
RESET
TOTAL PV
TOTAL
Input Mode UP
Output Mode F
A
4
3
A
5
4
3
2-87

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTT-1C-D24 and is the answer not in the manual?

Questions and answers

Ron Hurst
April 28, 2025

How to set oven or time on CTT-1-C-D24

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ctt-an-d24Ctt-1c-a120Ctt-an-a120

Table of Contents

Save PDF