LOGIX™ SERIES INSTALLER
QUICK-START SHEET

Logix Series Controllers

See: Determining If You Have a 740 or 760 Control on page
19 to identify your controller.
740 Controller - Electronic time clock control capable of doing
7-day (day of week) regeneration, or up to a 99 interval day
regeneration. This control will operate both in a conditioner
(softener) or filter mode with the same controller.
760 Controller - Electronic metered-demand (volumetric)
controller which regenerates based on the water usage of the
installation site. A calendar override is a standard feature on
this controller.
The Logix Series will operate on both the 255 and Performa
valve body series.
LCD Display
SU MO TU WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
DOWN Button
SET Button

Initial Power-up

Initial Power Up - (CAMSHAFT proceeds to HOME position)
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
• At initial power-up, the camshaft will need to rotate to
the HOME (in service) position.
• Camshaft may take 1-2 minutes to return to home position.
• Err 3 will be displayed until the camshaft returns to home.
• If more than 2 minutes elapses, verify that the motor
is turning the camshaft. If it is not turning, see the
troubleshooting section.
The Logix controller features a self-test sequence. At
NOTE:
first power-up of the control, you may see a number
such as 1.00, 1.02, 1.04, or 2.00, displayed. This is
an indication that the self-test is not completed. To
complete the test, verify that the turbine cable is
connected. Blow into the turbine port (valve outlet)
to spin the turbine. The controller will verify that the
turbine works and the self test will finish. Proceed
with the initial start up procedure.
PM
MIN
LBS
x2
KG
C
P
x100
H
UP Button
Manual
Regeneration
WE TH FR SA DAYS
AUTOTROL

Initial Start-up Step-by-step Instructions

Step 1: Program System Size
SU MO TU
WE TH FR SA DAYS
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
This step may have been performed by your system's OEM
manufacturer. In this case, proceed to step 2.
• Input system size - resin volume - in cubic feet or liters.
• Use UP and DOWN buttons to scroll through resin
volume choices.
• Choose the nearest volume to your actual system size.
• To choose a filter operation - press DOWN until an "F" is
displayed.
• Press SET to accept the system size you've selected.
• If incorrect setting is programmed, see "Resetting the
Control" section below.
Step 2: Program Time of Day
Time & Day
Capacity
Hardness
• While "12:00" is blinking, set the correct time of day.
• Use the UP and DOWN buttons to scroll to the correct
time of day.
• "PM" is indicated, "AM" is not indicated.
• Press SET to accept the correct time of day and advance
to the next parameter.
Step 3: Set Day of Week
Time & Day
Regen Time & Day
Hardness
• Press SET to make the arrow under SU flash.
• Use the UP and DOWN buttons to advance the arrow until
it is under the correct day of week.
• Press SET to accept and advance to the next parameter.
After steps 1-3, the controller will operate most systems.
Proceed to step 4 if further adjustments to your system's
programming is needed.
To exit the programming state, wait 30 seconds and the controller
will automatically put you into the normal operating mode.
740/760 Control 255 & Performa Series Valves (268, 268FA) Service Manual
®
SU MO TU
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU
WE TH FR SA DAYS
WE TH FR SA DAYS
SU MO TU
Salt
Capacity
WE TH FR SA DAYS
• 3