PROGRAMMING CONTINUED

700 Series Advanced Programming

SET
DOWN
arrow
The 700 Series controllers are designed to operate by only
setting the time of day and the day of the week. The remaining
settings have been set at the factory. These default settings
will work for most applications.
To change a setting:
Action
Key
Enter basic
SET
programming
Move to
UP or DOWN
desired
arrows
display
Enable setting
SET
to be changed
Change
UP or DOWN
setting
arrows
Save setting
SET
Return to
REGEN
operation
View history
SET and
values
DOWN
This level of programming is accessible by pressing the SET
button. The UP and DOWN arrows will step through the settings:
Time of day
Day of week
Time of regeneration
Number of days between regeneration (99 day timer)
Day of week regeneration (displays only when number of days
between regeneration equals zero) (7 day timer)
Amount of regenerant used per regeneration or filter
backwash time
System capacity (view only)
22 • AUTOTROL
740/760 Control 255 & Performa Series Valves (268, 268FA) Service Manual
®
UP arrow
For Regeneration
Duration
Display
Press and
Will show day of
Release
week
Press and
Will increment
Release
through the
displays
Press and
Display will flash
Release
Press and
Value changes and
Release
continues to flash
Press and
Display stops
Release
flashing
Press and
Normal operation
Release
display
Press and Hold
HO will be
for 5 seconds
displayed

Accessing History Values

The Logix control features a review level that displays the
operation history of the system. This is a great troubleshooting
tool for the control valve.
To access history values, press and hold SET and DOWN for
five seconds to view the "H" levels.

History Values

Description
H0
Resin volume initial setting
value
H1
Days since last regeneration
H2
Current flow rate
H3
Water used today in gallons/m
since Time of Regeneration
H4
Water used since last
regeneration in gallons/m
H5
Total water used since reset in
100s
H6
Total water used since reset in
1,000,000
H7
Average usage for Sunday in
gallons or m
3
H8
Average usage for Monday in
gallons or m
3
H9
Average usage for Tuesday in
gallons or m
3
H10
Average usage for Wednesday in
gallons or m
3
H11
Average usage for Thursday in
gallons or m
3
H12
Average usage for Friday in
gallons or m
3
H13
Average usage for Saturday in
gallons or m
3

Resetting the Logix Control

To reset the control:
1. Press and hold SET and DOWN simultaneously for 5 seconds.
2. H0 and the system's set resin volume (or "F" mode) will
be displayed.
3. If a history value other the "H0" is displayed, use the UP
button to scroll through the settings until "H0" is displayed.
4. To reset the control, press and hold SET for 5 seconds.
5. The control will be reset to an unprogrammed state.
6. Go to "Initial Set-up" section to reprogram control.
Resetting the control will delete all information
WARNING:
stored in its memory, except time and day.
This will require you to reprogram the control
completely from the initial power-up mode.
Range
Cubic feet or liters
0 – 255
0 – 47 GPM or 0 – 177 LPM
0 – 65536 gallons or
3
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3
0 – 65536 gallons or
0 – 6553.6 m
3