Result Codes

When a command is sent from the terminal the modem replies with a result code. The reply may be
either in Long Form i.e. text (V1) or in Short Form, i.e. a two digit code (V0). The result code in
Long Form is followed by <CR><LF> and in Short Form by <CR>. Using the Q1 command enables
the result codes. The result codes and their short forms are as follows:
00
OK
01
CONNECT
02
RING
03
NO CARRIER
04
ERROR
05
CONNECT 1 200
06
NO DIALTONE
07
BUSY
08
NO ANSWER
09
CONNECT 600
10
CONNECT 2 400
11
CONNECT 4 800
12
CONNECT 9 600
16
CONNECT 19 200
17
CONNECT 38 400
18
CONNECT 57 600
24
DELAYED
32
BLACKLISTED
33
FAX
34
+FCERROR
35
DATA
40
CARRIER 300
42
CARRIER 600
46
CARRIER 1 200
47
CARRIER 2 400
48
CARRIER 4 800
49
CARRIER 7 200
50
CARRIER 9 600
51
CARRIER 12 000
52
CARRIER 14 400
66
COMPRESSION: CLASS 5
67
COMPRESSION: V.42 bis
69
COMPRESSION: NONE
70
PROTOCOL: NONE
77
PROTOCOL: LAPM
80
PROTOCOL: ALT
81
PROTOCOL: ALT-CELLULAR
100
NOVRAM ERROR
101
NO NOVRAM
102
SWITCH ERROR
103
INACTIVITY TIMEOUT
6178-2203
The OK code is returned to acknowledge execution of a
command line.
The modem will send this result code upon connecting
with 300 baud.
Incoming ringing is detected on the line.
No carrier is detected.
The modem will send this result code when it's unable to
execute a command contained on the command line.
For connections with 1 200 baud.
No dial tone is received.
Busy (engaged) signal is detected on the line.
No answer from remote modem detected on the line until
the expiration of the time S7.
For connections with 600 baud on the DTE.
For connections with 2 400 baud on the DTE.
For connections with 4 800 baud on the DTE.
For connections with 9 600 baud on the DTE.
For connections with 19 200 baud on the DTE.
For connections with 38 400 baud on the DTE.
For connections with 57 600 baud on the DTE.
If dialled number not allowed to dial yet.
If dialled number is not allowed.
If it's a fax connection.
Error in fax connections.
Connected as data modem.
300 baud carrier.
600 baud carrier.
1 200 baud carrier.
2 400 baud carrier.
4 800 baud carrier.
7 200 baud carrier.
9 600 baud carrier.
12 000 baud carrier.
14 400 baud carrier.
MNP class 5 compression active.
V.42 bis compression active.
No compression active.
No error correction active.
LAPM error correction active.
MNP4 error correction active.
MNP10 with Cellular active.
Error in memory.
No memory mounted.
Error in switches.
Inactivity time limit reached.