Westermo TD-32/485 Installation Manual page 48

Tele modem v.32bis, galvanic isolation, transient protection, ce approved
Hide thumbs Also See for TD-32/485:
Table of Contents

Advertisement

Dial up with hardware signalling
Dial up can be made by applying an external signal to the DTR-pin in the RS-232/V.24 contact.
A typical application is an alarm signal from a PLC or another relay contact.
The modem reacts on the first rising edge which means that one pulse is sufficient.
The signal level should be in compliance with the RS-232/V.24 standard. If only a relay contact
is available the DSR-pin will provide a suitable voltage.
The modem does not have a redialling function. If necessary this must be handled by other
equipment connected. We advise the DCD signal to be used as a control indicating whether
connection was made or not.
AT&B1
AT&D3
AT&Z0=nn
Please also refer to "To use minicall", as the minicall and the dial-up with
hardware signalling can be used together.
48
External signal
Dial-up using DTR.
Hang-up if DTR goes low.
The number to dial, nn, is stored in memory position 0.