Westermo TD-32/485 Installation Manual page 22

Tele modem v.32bis, galvanic isolation, transient protection, ce approved
Hide thumbs Also See for TD-32/485:
Table of Contents

Advertisement

Hn – Disconnection
The command makes the modem either connect to or disconnect from the line.
H0
Disconnection "on-hook".
H1
Connection "off-hook".
Please also refer to S7
*Hn – MNP10 connection speed
This command controls the initial line speed during connection, between two MNP10 modems. The
value is written to S28 bit 6 and 7.
Connection is executed at maximum available speed. (Default)
*H0
*H1
Connection is executed at 1 200 Baud.
*H2
Connection is executed at 4 800 Baud.
Please also refer to AT\N
In – Identification Report
The command reports the requested result to the DTE connection, the terminal or the computer.
I0
Reports product code.
I1
Reports a precomputed checksum.
I2
Reports a precomputed checksum and compares it to the value stored in the program (I1).
I3
Reports firmware revision.
I4
Reports product identification information.
I5
Reports Country Code parameter.
I6
Reports modem data pump model and internal code revision.
&Kn – Flow Control
This command sets the flow control between the modem and the terminal.
The value is written to S39 bit 0, 1 and 2.
&K0
Disables flow control.
Enables RTS/CTS flow control. (Default)
&K3
&K4
Enables XON/XOFF flow control.
&K5
Enables transparent XON/XOFF flow control.
&K6
Enables both XON/XOFF and RTS/CTS flow control.
22
6178-2203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td-32