Response packet
OPCODE
Length
0xBE
0x01

SET_TRIGGER_CMD

Description
Set the trigger command
Parameters
Opcode, Param1, Param2, Param3
Parameter
Opcode (unsigned eight-bit)--opcode of command to be executed
Description
Param1, Param2, Param3 (unsigned eight-bits)--first, second, and third
parameter of the selected command (number of parameters ranges from 0 to
3 depending of the selected command)
Command packet
OPCODE
Length
0x3F
0x01 to
0x04
1
The length is variable, depending on the selected command.

TRIGGER_CMD?

Description
Query the trigger command
Parameters
NA
Parameter
NA
Description
Command packet
OPCODE
Length
0x40
0x00
U8 Address
Address (unsigned eight-bit)--Network address (2 to 31)
U8 Opcode, U8 Param1, U8 Param2, U8 Param3
1
Opcode (unsigned eight-bit)--Opcode of the command selected to
be executed as part of the trigger command (0x20 to 0x27)
Param1 (unsigned eight-bit)--Parameter 1 (if necessary) (0 to 9)
Param2 (unsigned eight-bit)--Parameter 2 (if necessary) (1 to 2)
Param3 (unsigned eight-bit)--Parameter 3 (if necessary) (1 to 200)
Parameters
Parameters
Parameters