Using Sk / Sp Emulation Mode; Using The Switch; Voltage Levels - JDS Uniphase SKB SERIES User Manual

Fiberoptic switch module
Hide thumbs Also See for SKB SERIES:
Table of Contents

Advertisement

Pin
Signal
19
D7
20
STROBE
1
21
GND
22
RESERVED reserved; internal use only; do not use
23
RESERVED reserved; internal use only; do not use
1
24
GND
25
RESET
1
Connect GND signal lines to common ground of the master.
Caution
If the reserved pins are used for any purpose, compatibility with future versions
of the SKB module can be compromised.

Using SK / SP Emulation Mode

The SKB switch can be run in a mode that emulates operation of the SK and SP product line. A
hybrid, parallel connector cable must be constructed. Contact JDS Uniphase for instructions on
cable pinouts.
Simultaneous operation of serial and parallel interface is not supported.

Using the Switch

Voltage Levels

All parallel interface signals are TTL compatible. The active state of each signal is outlined in
Table 8.
data line 7; most significant bit (MSB)
STROBE input, active low:
high-to-low pulse = read data lines and home line
high = ignore state of data lines and home line
This line is internally pulled high via 10 k ohm resistor to 5 V DC
shield
shield
resets the hardware (MCU reset)
Description
Operating and Maintenance Instructions – 22

Advertisement

Table of Contents
loading

Table of Contents